Cleaning The Engine Cooling System; Brake Maintenance; Adjusting The Parking Brake - Toro Reelmaster 3100-D Operator's Manual

Hide thumbs Also See for Reelmaster 3100-D:
Table of Contents

Advertisement

4.
If the coolant level is low remove the expansion
tank cap, add the specified coolant to the tank
until the coolant level is midway between the
marks on the side of the tank, and assemble the
cap to the tank.
Important:
Do not overfill the expansion
tank.
5.
Close and latch the hood.
Cleaning the Engine
Cooling System
Service Interval: Before each use or daily
Remove debris from the oil cooler and radiator daily.
Clean them more frequently in dirty conditions.
1.
Prepare the machine for maintenance; refer to
Preparing for Maintenance (page
2.
Raise the hood.
3.
Clean the engine area thoroughly of all debris.
4.
Remove the lower radiator shield
Figure 78
1. Radiator
5.
Clean both sides of the radiator area thoroughly
with water or compressed air
6.
Install the lower radiator shield.
7.
Close and latch the hood.
44).
(Figure
78).
g352363
2. Lower radiator shield
(Figure
78).

Brake Maintenance

Adjusting the Parking
Brake
Service Interval: Every 200 hours—Check the
adjustment of the parking brake.
1.
Prepare the machine for maintenance; refer to
Preparing for Maintenance (page
2.
Loosen the setscrew securing the knob to the
parking-brake lever
1. Parking-brake lever
2. Knob
3.
Rotate the knob until a force of 133 to 178 N (30
to 40 lb) is required to actuate the lever.
4.
Tighten the setscrew.
56
44).
(Figure
79).
Figure 79
3. Set screw
g008923

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Reelmaster 031704092100000317003171

Table of Contents