Baud Rate Settings
A baud rate is set by software by dividing the clock input (1.8432MHz). The baud rate in terms of
hardware can be set to a maximum of 115,200 bps for SERIALA, B. The baud rates available in practice
depend on the operating environment (cable, software, etc.). The table below lists typical baud rates and
their respective values to be written to the divisor latch register (LSB, MSB).
Table 6.4 Baud Rate Settings
Baud rate to be set
50
75
110
134.5
150
300
600
1200
1800
2000
2400
3600
4800
7200
9600
14400
19200
28800
38400
57600
76800
115200
153600
230400