Installation Setup - Airstream Cumberland EXPERT LA User Manual

Temperature controller
Table of Contents

Advertisement

EXPERT LA
4.5

Installation Setup

The following section shows how to customize the
controller for your particular application. It explains
how to enable and set the outputs of your control-
ler. Normally, this setup needs to be done only once.
Select:
Main menu
Setup*
User
Installation
*
A password may be required to access this menu (sec. 4.2).
Hint: use the right and left arrow key
to move up and down through the
display by pages.
Set the following parameters:
Number of feeders
The controller has 4 inputs that are used to
monitor the run time of feeder motors. En-
able the proper number of feeder inputs (0
to 4 feeders).
Number of heating stages
Enable the proper number of heating stages
(0 to 4 heating stages).
Use Heater Lo/Hi Fire?
Select "Yes" to activate the heating out-
puts' Lo & Hi fire option. This function al-
lows doubling the number of heating stages.
[This parameter is common to all programs].
Number of fan stages
Enable the proper number of fan stages
(0 to 12 fan stages).
The number of fan stages is limited by the stage
number that signals the beginning of tunnel venti-
lation. Refer to section 6.4 to select the first tun-
nel stage.
Installation
# Feeders
# Heater stages
Use Heater Lo/Hi Fire?
# Fan stages
# Clocks
# Natural Curtain
# Tunnel Curtain
# Light Programs
# Vent Doors/Inlets
Use 0-10V Output
Vent Door/Inlet 1 Mode
Vent Door/Inlet 2 Mode
Close Vents in Natural
Use
to navigate
Number of clock outputs
Enable the proper number of clock outputs
(0 to 2 clock outputs).
Number of natural ventilation curtains
Enable the proper number of natural ventila-
tion curtains (0 to 2 natural vent. curtains).
Number of tunnel curtains
Enable the proper number of tunnel curtains
(0 to 2 tunnel curtains).
Number of light programs
Enable the proper number of light programs
(0 to 8 light programs). Note that lighting pro-
grams are based on the animal age. Conse-
quently, enabling a light program automati-
cally enables age-based functions.
Number of vent doors
Enable the proper number of vent doors (in-
let) outputs (0 to 2 outputs).
EXPERT LA rev.00
Main menu
Setup
User
Install.
4
4
Yes
8
2
2
2
3
2
Yes
Time
S.P.
No
19