Probe Assignment - Airstream Cumberland EXPERT LA User Manual

Temperature controller
Table of Contents

Advertisement

EXPERT LA
4.7.3

Probe Assignment

Some outputs of the controller (heaters, 0-10V
output and curtains) operate according to the av-
erage temperature measured by chosen tempera-
ture probes. You must assign temperature probes
to each of these outputs.
Room Temperature Sensors
Most cooling outputs (misting output, tunnel fans,
etc.) operate according to the average tempera-
ture in the room. You must select what tempera-
ture probes are used to measure the room tem-
perature.
Settings
This section explain how to select temperature
probes that are used to measure the room tempera-
ture and how to assign temperature probes that
are used to control/ monitor the following outputs:
• Heaters 1-4
• 0-10V output
• Natural ventilation curtains
A template is available at the end of
this manual to write down your selec-
tion of sensors.
Heater 1 Probe Assignment
1
---
6
---
26
EXPERT LA rev.00
Main menu
Setup
Probe Assgn
Heater
2
3
4
5
---
---
---
---
7
8
---
---
Probe Set 2
In tunnel ventilation, some changes in airflow pat-
terns can distort the room temperature calculation.
For this reason, it is possible to make another se-
lection to measure the room temperature in tunnel
ventilation. The second probe set must be enabled
in the Installation Setup to use this function (see
section 4.5).
Select:
Main menu
Setup*
Probe Assignment
Select the desired output ** :
- Room;
- Probe Set 2;
- Heaters 1-4 ;
- Heaters 1-4 Hi fire (opt.) ;
- 0-10V output ;
- Natural ventilation curtain 1-2.
*
A password may be required to access this menu (sec. 4.2).
**
Only outputs that are enabled in the Setup menu are dis-
played (sec. 4.5).
Assign the desired temperature probes to
the selected output: select "" " to assign a
probe or select "- - - " for probes that are
not assigned to the output.