EXPERT LA
11.3 Alarm Settings
Select:
Main menu
Start/Stop*
Alarms
*
A password may be required to access this menu (sec. 4.2).
Temperature
Clean Mode
Low Alarm
High Alarm
Critical Alarm
Water 1 Spill Limit
Water 2 Spill Limit
Static Pressure Alarm
Low Alarm
High Alarm
Delay
Feed Monitoring?
Feeder 1 Max Time
Feeder 2 Max Time
Activate the alarm relay with
Water Spill
Lo Temperature
Hi Temperature
Lo Stat. Pres.
Hi Stat. Pres.
Defect. sensors
Comm. Error
Whisker Defect
Use
•
Set the following alarm limits:
Refer to the previous page to get further informa-
tion about these parameters).
•
Temperature Alarms
Clean mode: Set the temperature below
which a temperature alarm is set off in
clean mode.
Accessible if the Clean mode's low temp. alarm
is enabled (see sec. 4.10).
Lo/Hi alarm: Set the room temperature
below and above which a temperature alarm
is set off.
Main menu
Start/Stop
Alarms
Alarm Settings
Alarms
32.0 °F
60.0 °F
90.0 °F
100.0 °F
100 Lit
100 Lit
.010 "WC
.100 .WC
300 sec
Yes
5 min
None min
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
to navigate
Critical temperature: Set the absolute tem-
perature above which an alarm is set off.
Accessible if an outside temperature probe is
enabled (section 4.7.1).
•
Water spill limit
Specify the maximum amount of water that can
be consumed by each water meter per 15 min-
utes (0-10,000 gal or liters/15 min).
Accessible if a water meter is enabled (sec. 4.7.1)
•
Static pressure limit
Accessible if a static pressure probe is enabled
(section 4.7.1).
Low / High alarm: Set the pressure
levels below and above which an alarm
is set off.
Delay: The high or low pressure condi-
tion must be maintained on this period
of time before the controller sets off
the alarm. Set the static pressure alarm
delay to the desired value (in seconds).
•
Feeder monitoring
Select "Yes" if you want the controller to
monitor the run time of feeding inputs. If
this alarm condition is enabled, set the maxi-
mum run time of each feeder (in minutes).
Refer to section 4.8 to assign the relay that
must open in case of a run time alarm.
Accessible if feeders are enabled (section 4.5).
•
Activate the alarm relay:
Select "Yes" if you want the controller to
activate the alarm relay when the following
alarm conditions occur:
- Lo / Hi Temperature;
- Lo / Hi Static pressure;
- Water spill;
- Defective sensors: temperature
humidity, static pressure;
- Defective whisker switch.
[Alarm conditions that are activating the alarm
relay are common to all programs].
EXPERT LA rev.00