Rh Compensation Setup - Airstream Cumberland EXPERT LA User Manual

Temperature controller
Table of Contents

Advertisement

EXPERT LA
4.6

RH Compensation Setup

The controller offers different ways to compen-
sate for high and low relative humidity (RH) levels
in the barn. This section shows how to enable the
desired RH compensation functions.
Select:
Main menu
Setup*
User
RH Compens**
*
A password may be required to access this menu (sec. 4.2).
**
Accessible if a humidity sensor is enabled (sec. 4.7.1)
Enable or disable the following relative hu-
midity (RH) compensation options:
The following parameters are com-
mon to all programs of the controller.
RH compensation with heaters
The controller can compensate for high hu-
midity levels by activating heating outputs
in timer mode. Select "Yes" to use this com-
pensation method.
Mist Shutoff
The controller can deactivate the misting out-
put when humidity levels are too high. Se-
lect "Yes" to use this compensation method.
RH Compensation
RH Compens Heaters?
Use Mist Shutoff?
Use Mist on Lo %RH
Use Cool Cell Shutoff
Use
Misting on low humidity levels (% RH)
The controller can activate misting outputs
when humidity levels are too low. Select
"Yes" to use this compensation method.
Cool cell shutoff
The controller can deactivate the cool cell
output when humidity levels are too high.
Select "Yes" to use this compensation
method.
EXPERT LA rev.00