Curve Settings

Select:
Main menu
Set Points
SetP Curve*
*
Accessible if the temperature curve is enabled in the Instal-
lation setup (sec. 4.5). A password may also be required to
access this menu.
The following parameters can only be
modified while the curve is off.
If the curve is running, it is still possible
to adjust the value of all curve steps
simultaneously with the curve offset
parameter (see section 5.3.3).
Set the following parameters:
Current day
This is the current age of the animals. This
value may be changed to move backward
or forward on the curve. A change in the
current day also changes the animal age in
the "Age & mortality" menu.
Set point
The day set point is displayed.
Temperature Curve Program 1
Cur. Day
Set Point
day
day
10
day
15
day
20
day
25
day
30
day
35
day
40
day
45
day
50
Status
Use
to navigate
Day numbers
Set the day at which each step starts. The
day number refers to the animal age. It is
adjustable from -5 to 450 days. Negative
values are used to prepare the house before
letting the animals enter.
Can only be modified while the curve is disabled.
Temperature set points
Assign a temperature set point to each step
of the curve.
Can only be modified while the curve is disabled
or by using the curve offset function (sec. 5.3.3).
Status
Select "On" to activate the curve. Once the
curve is on, the controller automatically ad-
justs the set point between consecutive
points of the curve; for this reason, curve
steps cannot be modified while the curve is
running.
EXPERT LA rev.00
Main menu
Set Points
SetP Curve
0 day
70.0 °F
1
78.0 °F
75.0 °F
70.0 °F
65.0 °F
63.0 °F
61.0 °F
60.0 °F
60.0 °F
60.0 °F
60.0 °F
Off