Temperature Set Point Curve; Principle Of Operation - Airstream Cumberland EXPERT LA User Manual

Temperature controller
Table of Contents

Advertisement

EXPERT LA
5.3
Temperature Set Point
Curve
5.3.1

Principle of operation

The controller can automatically adjust the target
room temperature (day set point) over time by us-
ing a curve.
A curve is composed of 10 steps. Each step speci-
fies a day number and a temperature set point for
that day (the day number refers to the animal age).
Once the curve is activated, the controller changes
the set point every hour in a linear fashion between
consecutive steps of the curve. When the last step
is reached, the controller keeps using the tempera-
ture set point associated to that day.
SET POINT (°F)
78
76
74
72
70
68
66
64
62
60
DAY -5
DAY 0
34
EXPERT LA rev.00
Set Point Curve
DAY 10
DAY 15
DAY 20
DAY 25
Notes
Certain restrictions apply to reduce the
risk of errors:
- The highest possible day number is 450.
- Decreasing day numbers is not allowed.
- All ten steps must be specified. If you don't
need ten different steps, repeat the last tem-
perature for each unnecessary step.
DAY 30
DAY 35
DAY 40
DAYS