EXPERT LA
6.7

Cool Cells

The controller can control one cool cell output. This
cooling system reduces the air temperature by
evaporation of water into the air stream.
Principle of operation
The cool cell output can either operate according
to the inside temperature or outside temperature:
it starts running in timer mode when the inside (or
outside) temperature rises and reaches the output's
start temperature; the output stops when tempera-
ture falls below a user-defined value. It can also
stop when humidity levels are too high (see RH
Compensation in chapter 10).
If the cool cell output operates according to the
inside temperature, its start and stop temperatures
are related to the set point; this means they are
automatically adjusted when the set point changes.
That is not the case if cool cells operate according
to the outside temperature.
Operating Diagram of
Cool Cells
Cool cell
output
On
Off
Operating time range
The user can specify a time range during which
the cool cell output can run. This allows deactivat-
ing the output at night for instance.
Settings
*
**
Temperature
(inside or outside)
Select:
Main menu
Start/Stop*
Cool Cells**
A password may be required to access this menu.
Accessible if the cool cell output is enabled in the Installation
Setup (section 4.5).
Cool Cell Settings
Temperature
On
Temperature
Off Temperature
On
Time
Off Time
Start at
Stop at
Use
Set the following parameters:
Temperature: Select "inside" if the opera-
tion of cool cells is based on the inside tem-
perature; select "outside" if it is based on
the outside temperature.
On temperature: Select the temperature (in-
side or outside T°) at which the cool cell
output starts.
Off temperature: Select the temperature
(inside or outside T°) below which the cool
cell output stops.
On & Off times: Set the on & off times of
the cool cell timer.
Start & stop at: Specify the time range dur-
ing which the cool cell can run.
EXPERT LA rev.00
Main menu
Start/Stop
Cool Cell
Inside
85.0 °F
83.0 °F
15 sec
900 sec
6:00A h:m
9:00P h:m