6.5.2.2

Installing a 5.25" adapter module for removable trays

Requirement
• The device is equipped with the drive cage type A.
• There is no drive or any other component in the mounting location for 5.25" components.
• An original spare part, that is a 5.25" adapter module approved for this device, see notes
in section "Accessories and spare parts (Page 20)".
• The device is fully disconnected from the line voltage, see section "Switching off the
device (Page 43)".
• The device is open; see section "Open the device. (Page 53)".
Procedure
1. Unlock the drive mounting bar together with the blanking plate by pressing laterally against
the surfaces ① and push the drive mounting bar forward from the device in the direction of
the arrow.
2. Remove the blanking plate.
3. Push the 5.25" adapter for the removable racks from the front into the drive cage.
SIMATIC IPC1047E
Operating Instructions, 03/2021, A5E50259546-AA
Expanding and assigning parameters to the device
6.5 Drives
67