Replacing The Backup Battery - Siemens SIMATIC IPC1047E Operating Instructions Manual

Table of Contents

Advertisement

7.3.5

Replacing the backup battery

The battery is used to back up the CMOS data for the BIOS setup and the real-time clock.
Note
Note the following points:
• Check the maintenance interval.. You can find additional information in the section
"Maintenance intervals (Page 80)".
• Replace the lithium battery only with an identical one or with a battery type
recommended by the manufacturer, see under "Requirement".
Requirement
• For the current BIOS setup settings, see section "BIOS description (Page 101)".
• The device is fully disconnected from the line voltage, see section "Switching off the
device (Page 43)".
• The device is open, see the section "Open the device. (Page 53)".
• All cables on the device are unplugged.
• 1 lithium battery; for article number, see section "Accessories and spare parts (Page 20)"
Procedure
Danger from short circuit
Conductive materials cause a battery short-circuit or damage adjacent modules.
• Only use insulated materials as tools for the battery replacement.
• Do not touch any adjacent modules.
NOTICE
Damage to the battery
Grease residues from your hands damage the battery.
• Do not touch the battery with your hands.
• Use suitable gloves, for example.
Note
The configuration data of the device may be deleted after battery replacement, depending on
the BIOS setting. With BIOS setting "Profile: User", the configuration data of the device is
retained; only the date and time must be set again.
SIMATIC IPC1047E
Operating Instructions, 03/2021, A5E50259546-AA
CAUTION
Device maintenance and repair
7.3 Removing and installing hardware
85