1.2 Operating Systems

1.2 Operating Systems
This product is equipped with functions which interface with a control panel and a control
unit. If you use CCU-970, this product can support not only stand-alone VTR shooting but
also various shooting styles such as studio shooting and field shooting as a system camera.
Furthermore, you can choose and operate each control panel to be connected to the CCU,
for your purpose.
■ Example of Minimum Configuration of System Camera (1 camera, 1 OCP, 1 MCP)
Camera Head
CCU
COMM
■ Example of System Camera Configuration (Up to 8 cameras, 1 MCP)
Camera Head
CCU-1
WFM
COMM
CCU-8
6
PM
PM
PM
WFM
OCP
WFM
WFM
WFM CONT
MCP
OCP
PM WFM
WFM
PM
CONT
PM
CCU-1
WFM, COMM
CCU-8
PM, WFM, COMM
HDK-65C 1501 VER1 (U)
DC 12V
EXTERNAL
POWER
AC
PM
WFM
OUT
CSU
IN
MCP
Note:
By using an SE-H750, SE-H700
system expander together, this
product can operate as a full-
scale studio camera equipped
with a 9-inch viewfinder and a
full studio lens.
Note:
For Minimum operating System,
no MCP needed when OCP-200
is used.
When any MCP other than
MCP-200 is used, EXTERNAL
POWER is not necessary, and
the CP cable length is 300m at
the maximum.
Term:
OCP (Operation Control
Panel)
This control panel is used for
normal operation. Typically one
OCP is dedicated to one camera
chain.
Term:
MCP (Maintenance Control
Panel)
This control panel is used for
the maintenance and precise
adjustment of the camera in
studio shooting. By using a
memory card, you can save the
shooting condition on memory
and make setup easily. By
using a CSU together with an
MCP, you can maintain up to 32
cameras.
Term:
CSU (Camera Select Unit)
Used when controlling multiple
cameras. With using a MCP,
one CSU can control up to 8
cameras, and contains terminals
through which video is output
on the monitor from the selected
camera.

Advertisement