Ikegami HDK-65C Operation Manual page 106

High definition camera system
Table of Contents

Advertisement

5.2 Settings from the Menu
Menu Item
LENS SELECT
― NUMBER
― NAME
― (
)
― EXTENDER
― AUTO SEL
― FILE SET
― LENS TYPE
― AUTO x0.8 CONV
LENS SERIAL I/F
LEVEL ADJUST
― MASTER GAMMA
― MASTER PED
― MASTER FLARE
― DTL GAIN
ADJ CLR
PROCESS MODE
― GAMMA TYPE
― MATRIX
― HI-LIGHT DTL
― GAIN
LIMIT
― SMOOTH KNEE
DTL V FILTER
90
Initial
Setting Value
Setting
OFF
OFF, NO.1 to NO.8
(---------)
12 characters
AUTO SEL name display
(---------)
section
OFF, ON-1, ON-2,
OFF
ON-3, x0.8 CONV
OFF
OFF, ON
OFF
OFF, MANUAL, AUTO
OFF, C.PORTABLE,
C.STUDIO, C.FIELD,
OFF
F.PORTABLE, F.STUDIO,
F.FIELD
OFF
OFF, ON
ON
ON, OFF
0.0
-100 to +100
0.0
-100 to +100
0.0
-100 to +100
0.0
-100 to +100
READY,
READY
PUSH SET→CLR,
CANCEL
NORMAL
NORMAL,CUSTOM1-5
OFF
OFF, 1, 2, 3
ON
OFF, ON
0.0
1 to 100
0.0
-100 to +100
OFF, TYPE1,
TYPE-1
TYPE2, TYPE3
OFF
ON, OFF
HDK-65C 1501 VER1 (U)
Description, Remarks
Select the lens file number.
-If the lens code is obtained from the lens, (CODE SEL) is
displayed on the back of the lens number display.
-If AUTO SEL is ON, "AUTO SEL" is displayed on the back
of the lens number display.
Set the file name for each lens file.
Attaching the lens model name, etc. will make it easier to
know the correspondence between the lens number and lens.
Displays the lens name obtained from the serial lens.
Displays the extender state.
The lens file number is switched automatically according to
the model name obtained from the lens.
See (Page 92) for the FILE SET usage method.
To match the zoom tracking DTL operation characteristics
with the lens zoom characteristics, set the time of the lens
used in the camera.
OFF
: Game tracking DTL is OFF.
C.PORTABLE : Canon portable lens
C.STUDIO
: Canon studio lens
C.FIELD
: Canon field lens
F.PORTABLE : Fujinon portable lens
F.STUDIO
: Fujinon studio lens
F.FIELD
: Fujinon field lens
Set by lens file (NO.1-8).
Set automatic switching of the aspect ratio converter (X0.8)
internal lens.
If set to ON, it operates in linked motion with the output
aspect ratio of the down converter to carry out automatic
switching.
Set whether to respond to the serial interface of the lens or not.
Sets the master gamma value.
The gamma value decreases in the direction of " -100" and
increases in the direction of "+100".
Sets the master pedestal value.
The pedestal value decreases in the direction of "-100" and
increases in the direction of "+100".
Sets the master flare value.
The flare value decreases in the direction of "-100" and
increases in the direction of "+100".
Sets the detail amount.
The detail amount decreases in the direction of "-100" and
increases in the direction of "+100".
Returns the settings changed with LEVEL ADJUST to the
state prior to change as a group.
Selects the type of gamma curve.
NORMAL
: Normal gamma curve
CUSTOM1-5 : Custom gamma curve
(Refer to "MENU(3/4)>CUSTOM GAMMA DATA" for
editing the custom gamma data.)
There are independent settings for three channels of the
matrix, which can be switched.
Possible to increase the DTL level of the highlight part.
Sets the level value to be emphasized.
Level increases in the direction of +100.
Sets the upper limit for the emphasized DTD level.
The "-100" direction lowers the limit. The "+100" direction
raises the limit and lowers the DTL level.
SMOOTH KNEE is a function to adjust the compression
level of the brightness signal with KNEE. It can be selected
from the following three setting types.
TYPE1 : The compression rate of brightness is low.
TYPE2 : The compression rate of brightness is medium.
TYPE3 : The compression rate of brightness is high.
If the V filter of the DTL is ON, the resolution feeling in
direction V diminishes, making it possible to obtain an
image with less noise.
MENU DATA
ALL
VF
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fa-97

Table of Contents