Adaptec DURASTOR 6320SS Manual page 52

Durastor hard drive array
Hide thumbs Also See for DURASTOR 6320SS:
Table of Contents

Advertisement

DuraStor 412R/6320SS/7320SS Installation and User's Guide
Table 4-4
describes the status LEDs for this example.
Table 4-4 Drive Status LEDs – One-Touch Annunciation Example
Drive Slot
Status LED
1
On
2
On
3
Off
4
Off
5
Off
6
Off
7
Off
8
On
9
On
10
On
11
On
12
On
4-8
Description
Enclosure is in dual-bus mode.
SCSI host interface.
N/A
Switch 1 (A0) is in the DOWN position. This
sets the drive SCSI IDs of the slots to IDs 1, 2,
3, 4, 5, 6, 9, 10, 11, 12, 13, 14. It reserves IDs 0
and 7 for the host bus adapter, and SCSI ID
15 for the SAF-TE processor.
Switch 6 is in the DOWN position. This sets
the BAUD rate for the SAF-TE RS-232 serial
port to 9,600.
N/A
Switch 2 (A1) is in the DOWN position. This
sets the drive SCSI IDs of the slots to IDs 1, 2,
3, 4, 5, 6, 9, 10, 11, 12, 13, 14. It reserves IDs 0
and 7 for the host bus adapter, and SCSI ID
15 for the SAF-TE processor.
Switch 7 is in the UP position. This sets the
Delay Start mode to Disabled.
Controller is present.
Switch 3 (RD) is in the UP position. This
enables RAID addressing and is used when
configuring RAID mode (DuraStor 7320SS).
Switch 8 is in the UP position. This sets the
Remote Start mode to Disabled.
Controller is present.