SAFETY RULES AND OPERATING INSTRUCTIONS
WARNING
Explosive mixtures of Hydrogen gas are present
within battery cells at all times. Do not work
with or charge a battery in an area where open
flames (including gas furnace or water heater
pilots), sparks, cigarettes, or any other sources
of combustion are present. Always provide
ample ventilation in rooms where batteries are
being charged. Failure to do so may result in
severe bodily injury and/or property damage.
WARNING
Battery electrolyte is poisonous and dangerous.
It contains sulfuric acid. Avoid contact with
skin eyes or clothing. Wear rubber gloves and
safety glasses while servicing batteries. DO NOT
INGEST! This may result in severe bodily injury.
WARNING
The charger must be connected to a properly
grounded AC receptacle. Improper connection
will increase the risk of electric shock and can
cause severe personal injury or death.
WARNING
The Signet and X-Series chargers are for lead
acid batteries only. Charging other types of
batteries may cause the battery to burst or
explode causing severe personal injury and/or
property damage.
WARNING
DO NOT disassemble the charger. There are no
user serviceable components in the charger.
Refer all repairs to a qualified technician.
Incorrect repair or reassembly of the charger
can result in an explosion, electric shock, or
fire.
WARNING
Do not attempt to operate the vehicle while
charging the battery. Operating the charger and
vehicle at the same time may lead to damage
to the charger and/or the vehicle resulting in
personal injury and/or property damage.
Safety Rules
Page 16
CAUTION
The key switch must be in the "OFF" position
when charging the batteries. Failure to turn the
key switch "OFF" may result in damage to the
vehicles electrical system.

Taylor-Dunn X-Series Charger

This charger is rated for 115 VAC or 230 VAC
operation (nominal). Confirm the charger
installed is correct for the AC voltage power
source before connecting the charger.
Sealed batteries must be charged with a charger
configured for sealed batteries. Use of any other
charger will result in damage to the batteries
and premature failure of the batteries.
The X-Series chargers
a r e
d e s i g n e d
a s
automatic chargers. The
charger turns itself on
when it is plugged into
the wall outlet and turns
off when the batteries are
fully charged.
There is a user interface
on the charger. The
interface consists the
following:
1) Start/stop switch: When depressed, the charging
cycle will be terminated or restarted.
2) Charging status light: Indicates the current status of
the charging cycle. The light will start flashing when
the charging cycle is started. It will stop flashing
and remain ON when the cycle has completed.
Also used for fault indication along with the fault
light.
3) Low voltage start switch: When depressed, will
start the charge cycle if the battery voltage is too
low for an automatic start.
4) Fault light.: Displays faults after self diagnosis is
completed.
5) Circuit breaker.
6) Ammeter: Indicates the current flowing into the
battery during the charging cycle.
7) Self diagnostic switch: Starts the charger self
diagnosis procedure.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sc-100-36Sc-100-48

Table of Contents