SAFETY RULES AND OPERATING INSTRUCTIONS
WARNING
Explosive mixtures of Hydrogen gas are present
within battery cells at all times. Do not work
with or charge a battery in an area where open
flames (including gas furnace or water heater
pilots), sparks, cigarettes, or any other sources
of combustion are present. Always provide
ample ventilation in rooms where batteries are
being charged. Failure to do so may result in
severe bodily injury and/or property damage.
WARNING
Battery electrolyte is poisonous and dangerous.
It contains sulfuric acid. Avoid contact with
skin eyes or clothing. Wear rubber gloves and
safety glasses while servicing batteries. DO NOT
INGEST! This may result in severe bodily injury.
WARNING
The charger must be connected to a properly
grounded AC receptacle. Improper connection
will increase the risk of electric shock and can
cause severe personal injury or death.
WARNING
The Signet and X-Series chargers are for lead
acid batteries only. Charging other types of
batteries may cause the battery to burst or
explode causing severe personal injury and/or
property damage.
WARNING
DO NOT disassemble the charger. There are no
user serviceable components in the charger.
Refer all repairs to a qualified technician.
Incorrect repair or reassembly of the charger
can result in an explosion, electric shock, or
fire.
WARNING
Do not attempt to operate the vehicle while
charging the battery. Operating the charger and
vehicle at the same time may lead to damage
to the charger and/or the vehicle resulting in
personal injury and/or property damage.
CAUTION
The key switch must be in the "OFF" position
when charging the batteries. Failure to turn the
key switch "OFF" may result in damage to the
vehicles electrical system.
WARNING
This charger requires a standard household
15 Amp electrical circuit. Before plugging the
charger in, confirm that your charging station
is configured correctly.
DO NOT attempt to charge two vehicles on one
standard household 15A circuit.
Failure to confirm the proper charging station
configuration or attempting to charge two
vehicles may result in fire.

Lestronic II Charger Operation

The Lestronic II
charger is a semi-automatic charging
®
system. The charger will turn itself ON when the AC
power cord is connected to the AC power source and
turn itself OFF when the batteries are fully charged.
Refer to the data plate on the charger for the voltage and
type power required for the charger. When plugged in,
the charger assumes that the batteries require charging
and will charger for a minimum of approximately 4-hours.
This charger should not be plugged in until the batteries
are discharged beyond 50% or the batteries may be
overcharged.