Download Print this page

Ricoh G-P1 Technical Bulletin page 29

Advertisement

Model:
Model G-P1
Subject:
Controller firmware (NIB) release note for G-P1
From:
1st Tech. Support Sec. Service Support Dept.
Classification:
This RTB has been issued to announce the printer firmware (NIB) release information for
the Model G-P1 controller board.
NIB
Version
4.00
4.08.3
4.14.1
NIB
Version
1.01
1st mass production
1.04
Minor changes applied to improve reliability.
1.05
If the paper type setting is changed via WIM while "Permit Settings by
SNMPv1 and v2" is disabled, the browser will timeout. The paper type
setting change will not be saved.
SNMPv1/v2 will still send SNMP traps even if the SNMPv1/v2 function is
disabled.
Sometimes after a power cycle, the device will be unable to accept jobs
from standard TCP/IP or SDM ports.
If a lot of SNMP traffic is sent to the device, the SNMP buffer may become
full. The result of this is that the device will not be able to reply to SNMP
requests.
SDM for Admin, running on a client PC that is connected to both a 1394
and ethernet interface, will not be able to retrieve the 1394 hostnames of
devices.
The SNMP service may not start when the device is turned on. Utilities
using SNMP will not receive status updates from the device.
The device can accept multiple incoming diprint (port9100) sessions.
Communications via diprint (port9100) are now transmitted
asynchronously.
T
echnical
Troubleshooting
Mechanical
Paper path
Other (
)
Program No.
G1045234A
G1045234B
G1045234C
B
ulletin
Date:
Prepared by:
Part information
Electrical
Transmit/receive
Effective Date
1st mass production
March 2005 production
July 2005 production
Symptom Corrected
No.:
29-Jun-05
K. Moriizumi
Action required
Service manual revision
Retrofit information
PAGE: 1/1
RG104007

Advertisement

loading