Reissued: 15-Apr-05
Model:
General RTB
5.5 Firmware Update for Centronics (IEEE1284)
Note:
Firmware update via a centronics interface does not require a password.
The only method of recovery available via a centronics interface is an IC or SD
card.
1. Check the target firmware version by printing out the SMC sheet with SP5-990-4.
2. Set SP5-856-2 to a value of 1. This will configure the machine for firmware update
via the Centronics I/F.
3. Send the firmware to the target machine with the copy command.
C:\>copy/b "file name"
4. Cycle the machine's power (off then on).
5. Confirm the firmware version as shown in step 1.
6. Update all required firmware by repeating steps 1 to 5 as necessary.
T