YASKAWA MH180 Operating And Maintenance Manual page 55

Table of Contents

Advertisement

1
Item number
10
Cable harness in robot
11
Battery unit in robot
12
S, L, U, R, B and T-axes gear
Inspection intervals
Schedule (h)
Method
Visual inspection
with multimeter
Grease gun
Operation
Check the bushing between the connector on
the stand and the intermediate connectors by
manually moving the wires. Check the protective
3
coil.
).
4
Exchange
If a battery alarm appears or after the robot has
been operated for 36000 hours, the battery must
be exchanged.
Check for malfunctions (replace if necessary).
5
The grease
must be refilled every 6000 hours
and exchanged every 12000 hours (see Chapter
9.4.1 "Grease filling the main axes" and 9.4.2
"Grease filling the wrist axes").
To be per-
formed by:
1
2
3

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Yr-mh180-a00

Table of Contents