11.5
Connection of activation units and accessories
See sensor manuals for mounting and adjustments. Protective device shall comply with EN 12978.
Door mounted
When sensors are used in order to avoid contact with the door leaf it is required that the presence
detect sensor and the presence impulse sensor fulfills Performance Level = d according to EN ISO
13849-1. These sensors shall also be monitored (tested) by ASSA ABLOY SW100 door operator.
** Note! When using the quick connector, opening
and closing side will be reversed.
PS-4C
PRESS
TO OPEN
1 2 3 4 5
CU-ESD
1 2
1 3
CU-ESD
EXU-SI
3 4
EXU-SI
3 10 11 12
3 6
EXU-SA
EXU-SA
EXU-SA
EXU-SI
EXU-SI
3 7
Inner impulse
1
Outer impulse
2
Key Impulse
3
Presence impulse
4
Presence detection
5
Off
6
Kill impulse NO
7
*
Standard
1005088-en-22.0
Activation
SP51-M**
sensor
A B C D E F G H
1 2 3 4
6 1
2
(6 1
3)*
13 3
4
1 1 1 2
4 5 5
1 1 1
3
4
Issue 2021-02-24
Configue sensor SP33-M:
DIP A7 to ON (for primary sensor)
DIP B4 to ON for presence impulse
DIP B4 to OFF for presence detection
SP33-M
A C H B F D I E
1 1 1 2
4 5 5
5
5
1 1 1
3
4
5
5
A
Brown
B
Yellow
C
Pink
D
Violet
E
White
F
Blue
G
Red
H
Green
I
Black
J
Grey