Basic Wiring Diagrams Using Factory Pre-Wired Connection
Standard Function with Switches
y Doors are normally closed.
y Activating either switch will open both
doors. Door will close after hold open time
delay has expired.
Fail Secure Electric Strike 24VDC Wiring
y Doors are normally closed and latched.
y Activating switch will unlock electric strike
and door will automatically open. Door will
close after hold open time delay has expired.
y Door will remain locked during power failure.
16
6021/6031 Series (Push Side) Power Operator
Copyright © 2019, 2023, ASSA ABLOY Accessories and Door Controls Group, Inc. All rights reserved. Reproduction in whole
or in part without the express written permission of ASSA ABLOY Accessories and Door Controls Group, Inc. is prohibited.
Approved 2023-01-24
Wall Switch, Card
Reader, Key Switch, etc.
(Normally Open
Momentary dry contacts)
Wall Switch, Card
Reader, Key Switch, etc.
(Normally Open
Momentary dry contacts)
Wall Switch, Card
Reader, Key Switch, etc.
(Normally Open
Momentary dry contacts)
24VDC
Electric Strike
(Fail Secure)
80-9360-1027-020 Rev 5 01/23