Basic Double Door Wiring Diagrams Using Factory Pre-Wired Connection
Standard Function with Switches
Follower Unit
Fail Secure Electric Strike 24VDC Wiring
Follower Unit
24VDC
Electric Strike
(Fail Secure)
Follower Door
18
D6011/D6051 Series Double Unit Pull Side Power Operator
y For Master/Follow or Master-Coord/Follow only (Sync Cable must be used to
connect inverters.)
y Doors are normally closed.
y Activating either switch will open both doors. Door will close after hold open
time delay has expired.
Wall Switch, Card
Reader, Key Switch, etc.
(Normally Open
Momentary Dry Contact)
y For Master/Follow or Master-Coord/Follow only (Sync Cable must be used to
connect inverters.)
y Doors are normally closed and latched.
y Activating switch will unlock electric strike and door will automatically open.
Door will close after hold open time delay has expired.
y Door will remain locked during power failure.
24VDC
Electric Strike
(Fail Secure)
Follower Door
Wall Switch, Card
Reader, Key Switch, etc.
(Normally Open
Momentary Dry Contact)