Storage, transport and unpacking

3
Storage, transport and unpacking
Safety information
Storage
14
WARNING!
The transporting of pumps which have been used with radio‐
active feed chemicals is forbidden!
They will also not be accepted by ProMinent!
WARNING!
Only return the metering pump for repair in a cleaned state
and with a flushed liquid end - refer to the chapter "Decom‐
missioning"!
Only return metering pumps with a completed Decontamina‐
tion Declaration form. The Decontamination Declaration con‐
stitutes an integral part of an inspection / repair order. A unit
can only be inspected or repaired when a Declaration of
Decontamination Form is submitted that has been completed
correctly and in full by an authorised and qualified person on
behalf of the pump operator.
The "Decontamination Declaration Form" can be found at
www.prominent.com.
CAUTION!
Danger of environmental and material damage
The unit can be damaged or oil may escape due to incorrect
or improper storage or transportation!
The unit should only be stored or transported in a well
packaged state - preferably in its original packaging.
Only transport the unit with the locking screw - not the
bleed plug - fitted to the oil filling opening.
The packaged unit should also only be stored or trans‐
ported in accordance with the stipulated storage condi‐
tions.
The packaged unit should be protected from moisture
and the ingress of chemicals.
CAUTION!
Danger of environmental damage
Pumps with a liquid end are supplied filled with oil.
When transporting, take care that no oil can escape.
Personnel:
n
1.
Plug the caps on the valves.
2.
Check whether the sealing screw is in place on the oil filler neck.
3.
Preferably place the pump standing vertically on a pallet and secure
against falling over.
4.
Cover the pump with a tarpaulin cover - allowing rear ventilation.
Store the pump in a dry, sealed place under the ambient conditions
according to chapter "Technical Data".