Safety chapter
Information in the event of an emergency
Safety information relating to the operating
instructions
Safety equipment
Fixed, isolating protective equipment
Other safety equipment - ATEX
Requirements, if the motor is being
installed independently
12
In the event of an electrical accident, disconnect the mains cable from the
mains or press the emergency cut-off switch fitted on the side of the
system!
If feed chemical escapes, also depressurise the hydraulic system around
the pump as necessary. Adhere to the safety data sheet for the feed
chemical.
Prior to commissioning the system or system component, the system oper‐
ator is obliged to obtain the latest safety data sheet from the supplier for
the chemicals / resources to be used with the system. The operator should
create the legal framework for safe operation of the system or system
component, such as for example the preparation of operating instructions
(operator duties), based on the information provided in the data sheets
concerning health and safety, water and environmental protection and
taking into consideration the actual operating environment on site.
During use of the pump all such parts should be secured in their position.
Protective equipment
Protective cowling above the motor
fan
Terminal box cover, motor
Flange cover, side
Only with add-on power end: Motor
connection cover
Only with additional equipment:
Their corresponding parts
* Only if required by the operating instructions and if the mains cable
remains disconnected from the mains voltage.
WARNING!
The following safety note must be stuck to pumps that
contain parts made of electrically non-conducting plastic.
Ensure that the label is always fitted and legible.
Fig. 2: @
The operator must be able to:
for ATEX motors: perform an ignition hazard assessment
n
perform a risk assessment
n
create and attach a nameplate
n
create an EC Declaration of Conformity
n
adapt the operating instructions, if necessary
n
correctly install the motor
n
May only be removed by*:
Service
Electrical technician, ATEX elec‐
trical technician, customer service
Service
Service
Technical personnel, service
WARNING
Electrostatic charge may
cause an explosion!
Clean plastic parts very
carefully using a damp cloth!