Assembly

6
Assembly
Motor installation - for versions without a
motor
18
Compare the dimensions on the dimensions sheet and
pump.
1.
Select a suitable motor - it must correspond to the data of one of the
motors from the table "Motor data" - see Chapter "Technical data"
WARNING!
In an area at risk from explosion, EX applies to
selected equipment and methods!
2.
Fit the motor correctly on the flange (qualified personnel).
Observe the clutch operating instructions!
WARNING!
In an area at risk from explosion, EX applies to
selected equipment and methods!
With a dog clutch: The claw on the motor shaft must be fixed at the
correct height, see Fig.
motor' on page 18
3.
As you have converted an "incomplete machine" into a complete
machine, you must perform a conformity assessment, risk assess‐
ment, create an EC Declaration of Conformity, fit a company name‐
plate, ... .For ATEX pumps: additionally perform an ignition hazard
assessment
4.
Complete the pump documentation / operating instructions.
Ä 'Motor installation - for versions without a