Safety chapter
Qualification of personnel
8
Pumps without the relevant nameplate (and the respective EC Decla‐
n
ration of Conformity) for pumps for potentially explosive atmospheres
must never be operated in potentially explosive atmospheres.
The pump is not intended for the metering of gaseous media and
n
solids.
The pump is not intended for the metering of explosive substances
n
and explosive mixtures.
The ATEX version is not intended for the metering of electrically non-
n
conductive media (conductivity less than 50 pS/m).
The ATEX version must not be exposed to any ionising radiation,
n
electromagnetic high frequency radiation in the range 10
or ultrasound without measures according to EN 1127-1.
The pump is not intended for unprotected outside use.
n
The pump is only intended for industrial use.
n
The pump should only be operated by trained and authorised per‐
n
sonnel, see the following table.
You are obliged to observe the information contained in the operating
n
instructions at the different phases of the device's service life.
You are obliged to observe the information contained in the operating
n
instructions of the accessory devices at the different phases of their
respective service lives.
Task
Storage, transport, unpacking
Assembly
Planning hydraulic installation
Hydraulic installation
Installation, electrical
Start up
Operation
Maintenance, repair
Decommissioning, disposal
Troubleshooting
Explanation of the table:
Qualified personnel
... 3x10
4
Qualification
Instructed person
Technical personnel, service
Qualified personnel who have a
thorough knowledge of metering
pumps.
In the area at risk from explosion:
ATEX qualified person, ATEX elec‐
trical technician
Technical personnel, service
Electrical technician,
In the area at risk from explosion:
ATEX electrical technician
Qualified personnel
In the area at risk from explosion:
Qualified personnel with ATEX
training; checking of the electrical
installation: recognised competent
person
Instructed person
Technical personnel, service
Technical personnel, service
Qualified person, electrical techni‐
cian, instructed person, customer
service - dependent on the require‐
ment
In the area at risk from explosion:
ATEX electrical technician;
checking of the electrical installa‐
tion: recognised competent person
Hz
15

Advertisement