Siemens 6GA7202-2AA10-1BF1 Operating Instructions Manual page 97

Simocrane censor camera measuring system
Table of Contents

Advertisement

Connection
In this group, you set the parameters for the connection interfaces.
Table 8-24
Connection
Parameter
Possible values
Source
Deactivated
Debouncing
Deactivated
Text
Result
Control
Source program for
saving
Diagnostics transfer
In this group, you specify the parameters for the transfer of diagnostic data.
Note
Transfer of images or data records
If you have set "Stack" as the buffer type under "Settings > Options > Diagnostics & monitoring
> Report", images and data records are only transferred until the stack is full.
SIMOCRANE CenSOR
Operating Instructions, 07/2021
Default
DI/DO
8
None
None
UDP
PROFINET IO
DI/DO
None
DI/DO
PROFINET IO
DI/DO
DI/DO
PROFINET IO
New
New
1
2
...
15
Description
Not relevant for CenSOR
Specify the interface over which the result text is output.
None: The result string is not output.
UDP: The result string is output via a UDP connection.
PROFINET IO: via PROFINET IO;
depending on the "IP mode" input box in the "Commu‐
nication" → "Interfaces" menu
Note
The result string can only be output via PROFINET IO if
you have selected the value "PROFINET IO" in the "Con‐
trol" drop-down list (see below).
Not relevant for CenSOR MV540 H
Specify the interface over which the signals (DISA, SEL0,
SEL1, SEL2, SEL3, TRN, RES, IN_OP, TRD, RDY) are transfer‐
red.
DI/DO: DI/DO interface (possible only when "Text" =
"PROFINET IO")
PROFINET IO; depending on the "IP mode" input box in
the "Communication" → "Interfaces" menu
Select the source program that the controller accesses as a
template. The controller creates new programs based on
the selected source program.
Parameterization
8.4 Settings
95

Advertisement

Table of Contents
loading

This manual is also suitable for:

6ga7202-2aa22-0ba1

Table of Contents