Installation/connection
6.3 SIMOCRANE CenSOR for an outdoor crane
Reflector
Risk of electric shock
The retroreflective reflectors for the outdoor crane are equipped with a 230 V AC foil heater. The
heater is attached inside the housing.
During operation, a dangerous voltage is present in the heater. A damaged heating foil can
result in severe injury or death.
• Work on the retroreflective reflectors is only permitted in the no-voltage state.
• Do not damage the foil heater.
• Wire the reflector to 230 V AC:
– 230 V, 3 x 0.75 mm², open cable end
• Wire the reflector power supply according to the circuit diagram. The circuit diagram is on the
SIMOCRANE CenSOR product DVD.
The following table lists the pin assignment of the cable:
Table 6-3
ID
L1 / phase
N neutral
PE
Diagnostics PC (during commissioning)
Connect the diagnostics PC to the computer unit via an Ethernet cable, either directly or via a
switch.
46
WARNING
Pin assignment of the cable
Power
230 V AC
Ground PE
Operating Instructions, 07/2021
SIMOCRANE CenSOR