Siemens 6GA7202-2AA10-1BF1 Operating Instructions Manual page 86

Simocrane censor camera measuring system
Table of Contents

Advertisement

Parameterization
8.2 Application
3. Enter these values (K1, K2, S1, S2) in the two formulas:
– Scale = (S1-S2) / (K1-K2)
– Offset = S1 – resolution * K1
4. Enter the following calculated values under "Program" → "CenSOR" → "Measured values for
parameters": "Scale" and "Offset"
Figure 8-8
Output parameters
Parameter
Possible values
X measured value
-10 000 ... +10 000 mm
Offset
X measured value
0 ... 10 s
Smoothing time
Y measured value
-10 000 ... +10 000 mm
Offset
Y measured value
0 ... 10 s
Smoothing time
Skew
-180° ... +180°
Offset
84
Parameterizing external distance
Default
0
0.00
0
0.00
0.00
Description
Calibration value for deflection in the X direc‐
tion
Smoothing time for smoothing of deflection
in the X direction
Calibration value for deflection in the Y direc‐
tion
Smoothing time for smoothing of deflection
in the Y direction
Calibration value for the skew measured val‐
ue