Quality values
The "Quality values" group is displayed as soon as a program is started.
This box contains an overview of the most important results of the last image processing
operation. To view a detailed description of a measured value, move the mouse over the quality
code (e.g. CPX) and a tooltip with more information will open.
Note
Display of values
These values are also displayed when you move the mouse over the reflector in the camera
image.
Table 8-11
Variable
Security
CPX
CPY
CDI
CRO
CR2
CSZ
CEX
CGN
Info statistics
The "Info statistics" group is displayed automatically as soon as a program is started.
The statistical information on the relevant number of processing procedures and read
operations is provided as a percentage (%).
Table 8-12
Menu command
or parameter
Total counter
Temporary error
Read
NOK
SIMOCRANE CenSOR
Operating Instructions, 07/2021
Quality values / measured values
Meaning
Detection reliability
X direction
Y direction
Distance
Skew
Skew2
Size
Exposure time
Gain
Info statistics
Description
Absolute number of total processing procedures
Not relevant for CenSOR
•
Absolute number of successful image processing procedures
•
Relative number of successful image processing procedures
•
Absolute number of unsuccessful image processing procedures
•
Relative number of unsuccessful image processing procedures
Explanation and unit
Detection reliability of the reflector as a percentage
Deflection of the reflector in the X direction in mm
Deflection of the reflector in the Y direction in mm
Distance between camera and reflector in mm
Skew of the reflector in degrees
Skew of the additional reflector in degrees (only if ac‐
tivated)
Edge length of a white reflector area in pixels
New exposure time in µs
New value for brightness
Parameterization
8.2 Application
73