Ethernet
In this group, you set the parameters for the Ethernet interface.
Table 8-18
Ethernet
Parameter
Possible values
IP mode
IP address
xxx.xxx.xxx.xxx
(only if IP mode =
manual or DHCP
server)
Subnet mask
255.xxx.yyy.zzz
Gateway
xxx.xxx.xxx.xxx
SIMOCRANE CenSOR
Operating Instructions, 07/2021
Default
DHCP
DHCP
Manual
PROFINET (FB79)
PROFINET (Ident
profile)
0.0.0.0
255.255.255.0
0.0.0.0
Description
Assignment of the IP address to the camera in the network:
DHCP Automatic (DHCP = Dynamic Host Configuration
Protocol)
Manual: Manual assignment
PROFINET (FB79) / PROFINET (Ident profile):
Automatically by the I/O controller
IP address of the Ethernet interface of the camera.
(An IP address consists of four numbers separated by peri‐
ods; each of these numbers is in the range 0 to 255.)
The subnet mask indicates which part of the IP address
specifies the network and which part specifies the camera:
If a bit is set in the binary representation of the subnet
mask, the corresponding bit of the IP address belongs to the
network address. If no bit is set, the bit belongs to the ad‐
dress of the camera.
In binary terms, xxx.yyy.zzz requires that the left part be
made up of ones without a gap and the right part be made
up of zeros without a gap. Example: 11111111.10100000
is not permitted.
Note also: zzz ≤ 254
Gateway IP address
IP address of the network node that can establish connec‐
tions from within the current subnet.
This is always required when there are devices in more than
one subnet. In this case, you can only establish connections
from the camera to other devices (e.g. to the (S)NTP server)
via the gateway.
Your network administrator must usually let you know if all
the devices are in the same subnet.
Notes
If the (S)NTP server is not addressed by the camera, the
gateway IP address is not required.
If a broadcast address is configured as the gateway IP
address, the camera cannot be configured using the Pri‐
mary Setup Tool (PST) or with the "Edit Ethernet node..."
functionality of the SIMATIC Manager. In this case, it is
also not possible to read out the configuration of the
camera using these programs.
Parameterization
8.4 Settings
91