5.3 ADVANCED SETTINGS
Event masks have two possible settings, YES or NO. If an action (e.g. the trip of a protection function) is set as
YES, when the trip takes place an event will be generated. If it is set as NO, no event will be generated.
EVENT
Phase A 87 1 Pickup
Phase B 87 1 Pickup
Phase C 87 1 Pickup
87 1 Pickup
Phase A 87 2 Pickup
Phase B 87 2 Pickup
Phase C 87 2 Pickup
87 2 Pickup
General Pickup
Phase A 87 1 Trip
Phase B 87 1 Trip
Phase C 87 1 Trip
87 1 Trip
Phase A 87 2 Trip
Phase B 87 2 Trip
Phase C 87 2 Trip
87 2 Trip
5
General trip
87 1 Disable by input
87 2 Disable by input
General Trip enable/disable by digital input
Protection status: in service/out of service
Digital output1 active/non active
Digital output 2 active/non active
Digital output 3 active/non active
Digital output 4 active/non active
Digital input 1 active/non active
Digital input 2 active/non active
Settings change disabled by digital input
Trip operation by digital input
Trip operation by command
Auxiliary digital output latch reset
Group 2 selection by digital input
Oscillo trigger by digital input
86 Status
Reset 86
Oscillography trigger by command
Settings change
EEPROM Failure
User settings/Factory settings
5-6
ENERVISTA MII SETUP
Phase A 87 1 Pickup
Phase B 87 1 Pickup
Phase C 87 1 Pickup
87 1 Pickup
Phase A 87 2 Pickup
Phase B 87 2 Pickup
Phase C 87 2 Pickup
87 2 Pickup
General Pickup
Phase A 87 1 Trip
Phase B 87 1 Trip
Phase C 87 1 Trip
87 1 Trip
Phase A 87 2 Trip
Phase B 87 2 Trip
Phase C 87 2 Trip
87 2 Trip
General trip
87 1 Disable by input
87 2 Disable by input
Trip disabled(by DI)
Protection status
Output 1
Output 2
Output 3
Output 4
Digital input 1
Digital input 2
Sett. change disable
Trip operation by input
Trip operation by command
Reset latch aux
Settings group change
Oscillo trigg by DI
86 Status
Reset 86
Oscillo trigg by comm
Settings change
EEPROM Failure
User settings
MIB High Impedance Bus Differntial Relay

5.3.6 EVENTS AND OSCILLOGRAPHY MASKS

DEFAULT
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
5 SETTINGS
RANGE
STEP
Y/N
NA
Y/N
NA
Y/N
NA
Y/N
NA
Y/N
NA
Y/N
NA
Y/N
NA
Y/N
NA
Y/N
NA
Y/N
NA
Y/N
NA
Y/N
NA
Y/N
NA
Y/N
NA
Y/N
NA
Y/N
NA
Y/N
NA
Y/N
NA
Y/N
NA
Y/N
NA
Y/N
NA
Y/N
NA
Y/N
NA
Y/N
NA
Y/N
NA
Y/N
NA
Y/N
NA
Y/N
NA
Y/N
NA
Y/N
NA
Y/N
NA
Y/N
NA
Y/N
NA
Y/N
NA
Y/N
NA
Y/N
NA
Y/N
NA
Y/N
NA
Y/N
NA
Y/N
NA
GEK-106426B

Advertisement

Table of Contents
loading

This manual is also suitable for:

90.017.102

Table of Contents