Auto Find - Automatically Setting the Sensor Offset (Cont)
10.
Click the [AutoFind] button, a message will appear asking you to place
a sheet of media in the cutter, and click OK, then the Intec ColorCut
SC5000, will load the sheet automatically from the feeder and use the Pen
Calibration Tool, to
repeatedly draw a
spiral pattern
simulate a registration
mark. it will then move
the Vision3 sensor
over to find the mark
and automatically
enter the values into
your Sensor Offset X
and Y settings. Once
completed you will
see a confirmation
message.
You can now close this window, the calibration for ColorCut Pro is now
complete.
If you do not set the X and Y Sensor offset values (either using the
AutoFind function - or manually) then the cutter will not cut accurately.
Please ensure you have done this. However once done, this should
not need to be repeated.

9.6 Units of Measurement

ColorCut Pro can be operated in Metric (mm) or Inches (Imperial). Use the Units
control to set the measurement units to your preference.