3.2.8 P-12 = 7: Control via CAN with internal acceleration and deceleration ramps
P-15
DI1
(terminal 2)
0
START
1
Not permissible
2
Not permissible
3
START
4
Not permissible
5
Not permissible
6
START
7
START
8
Not permissible
9
Not permissible
10
Not permissible
11
Not permissible
12
Not permissible
13
START
14
Not permissible
15
FWD
16
FWD
17
FWD
Table 16: P-12 = 7: Control via CAN with internal acceleration and deceleration ramps
DI2
(terminal 3)
No function
Select BUS REF/f-Fix1
Select BUS REF/AI1 REF
Select BUS REF/DIG REF
No function
Select f-Fix/BUS REF
Select f-Fix4/BUS REF
Select BUS REF/f-Fix4
DC1...E1 Variable Frequency Drives 11/16 MN040022EN www.eaton.com
3.2 Configuration of the control signal terminals
DI3/AI2
(terminal 4)
No function
EXTFLT
EXTFLT
EXTFLT
EXTFLT
Select Fire Mode/Normal OP
Select Fire Mode/Normal OP
Select Fire Mode/Normal OP
3 Control signal terminals
DI4/AI1
(terminal 6)
No function
No function
AI1 REF
No function
No function
Select f-Fix4/f-Fix2
No function
No function
23