5 Parameters

5.1 "Monitor" parameter group

5 Parameters
5.1 "Monitor" parameter group
Parameter
Designation
P00-01
Analog Input1
P00-02
Analog Input2
P00-03
Frequency Reference
P00-04
DI1 Status
DI2 Status
DI3 Status
DI4 Status
DI5 Status
P00-05
PID1 Output
P00-06
DC-Link Voltage Ripple
P00-07
Motor Voltage
P00-08
DC-Link Voltage
P00-09
Heatsink Temperature
P00-10
t-Run
P00-11
t-Run since Trip
32
The following tables use a number of acronyms. These acronyms are defined
below:
Abbreviation
Meaning
Min. value
Minimum value
Max. value
Maximum value
WE
Default setting (the parameter's value when using the device's
factory settings)
None of the parameters in parameter group 0 can be modified
by the user, i.e., they are read-only parameters.
Table 24: "Monitor" parameter group
Min. value
0
0
-P-01
0
0
0
0
0
0
0
0 V
0 V
-20 °C
0 h
0 h
DC1...E1 Variable Frequency Drives 11/16 MN040022EN www.eaton.com
Max. value
Description
100%
Analog Input 1
Level of the signal applied to analog input 1 after
scaling and offsets have been applied.
100%
Analog Input 2
Level of the signal applied to analog input 2 after
scaling and offsets have been applied.
P-01
Frequency Reference in Hz.
Will be calculated into rpm when motor data are
available.
Value of the drive internal digital reference.
1
Status of the Digital Inputs
1
Status of the digital inputs starting on the left hand
side with digital input 1 etc.
1
1
1
100 %
PI(D) controller 1 Output
1000 V
DC-Link Voltage Ripple
600 V AC
Instantaneous output voltage
1000 V DC
Instantaneous DC Link Voltage
100 °C
Instantaneous Heatsink Temperature
99999 h
Total operating time of the drive since the date of
manufacture
65000 h
Total operating time of the drive since the last trip
occurred

Hide quick links: