Lock Kick (Level 5) - Assa Abloy SW200 Installation And Service Manual

Hide thumbs Also See for SW200:
Table of Contents

Advertisement

16.6

Lock kick (Level 5)

a Disconnect batteries if any.
b Disconnect the mains.
c Press the LEARN BUTTON (LRN) and keep it depressed.
d Connect the mains.
e Watch the ERROR LED.
3 s
f
Release the LEARN BUTTON after 5 flashes (LED is out).
g Identify the current lock kick status
The ERROR LED flashes an amount of short flashes that correspond to the status number.
After a short pause the LED will repeat the status number and so on.
h Changing the status
If you push the LEARN BUTTON once, the status number will increase. When you have reached
the highest status number it will start at number one again.
• Push the button until you get the requested lock kick status, 1 = Basic (default), 2 = Enhanced
• Disconnect the mains
Next time the mains is connected, the operator will use the new status setting.
1009728-en-9.0