Assa Abloy SW200 Installation And Service Manual page 62

Hide thumbs Also See for SW200:
Table of Contents

Advertisement

13 Start-up
d Open the door to required open position, plus approx. 15 mm, by turning the potentiometer
SPTE on the CU-200, clockwise.
SPTE
e When stop arm is on top of the operator, lift the door stop arm up and mount it on the splines,
as close as possible to the stop block 1). Fine-adjust if necessary with the screw on the stop arm
2).
1)
f
When stop arm is on the bottom of the operator, loosen the stop ring and the stop arm. Mount
the stop arm on the splines, as close as possible to the stop block 3). Mount the stop ring. Fine-
adjust if necessary with the screw on the stop arm 4).
3)
62
Issue 2021-02-24
2)
4)
≈ 95°
1009728-en-9.0

Advertisement

Table of Contents
loading

Table of Contents