High Pressure Switch Has Shut Down The Unit - Wine Guardian Sentinel Series Installation, Operation And Maintenance Manual

Wine cellar cooling systems
Table of Contents

Advertisement

Possible Cause:
Piping from unit to drain is trapped
Trap plugged
Condensate pan plugged
Unit not level
Unit is running properly, but the sound of the unit is objectionable
Possible Cause:
Noise is from airflow
Noise if from unit

High Pressure Switch has Shut Down the Unit

Every Wine Guardian unit has a manual reset high pressure switch in the refrigeration system.
This switch shuts the compressor and condenser down if the head pressure in the system is too
high. It is intended to protect the compressor. Restricted airflow through the condenser is the most
common reason for the pressure to become too high. This can be caused by dust covering the
filter or an obstruction blocking the airflow in the duct or grille.
Possible Cause
Head pressure in unit is too high because an
obstruction is restricting air flow
68
Solution:
Re-pipe to remove external traps
Clean trap
Remove blockage and clean
Level with shims
Solution:
Redirect airflow
Add baffles
Add insulated ductwork
Add sound baffle between unit and occupied
Solution
Remove the obstruction in the duct or grille or
clean the filter. Then restart the unit after
resetting the high-pressure switch