46
Setting 30
• Press "Settings" button to advance to
Setting 30
• Press the "Up" or "Down" buttons to adjust
to the desired setpoint.
1 = Remote User interface #1 mounted
within the wine room space and enabled
2 = Remote User interface #2 mounted
within the wine room space and enabled
3 = Remote User Interface #1 disabled -
will display only and can be mounted
outside of wine room
4 = Remote User Interface #2 disabled -
will display only and can be mounted
outside of wine room
Setting 31
• Press "Settings" button to advance to
Setting 31.
• Press the "Up" or "Down" buttons to adjust
to the desired setpoint.
Each system needs all devices to be on the
same RF channel.
0 = RF disabled - system must be
hardwired
1 through 12 = RF enabled and 12
channels available
Settings 32-39
Reserved for additional fields.
Setting 40
• Press "Settings" button to advance to
Setting 40.
Not Available
Reserved for Thermistor
Setting 41
• Press "Settings" button to advance to
Setting 41.
Not Available
Reserved for Thermistor