Advertisement

Cleaning the Filters

The condenser coil is provided with a reusable, washable air filter. The filter protects the coil
from becoming coated or plugged by dust. Frequency of cleaning the filters is based on the
amount of dust or dirt generated in the cellar or basement.
1.
Remove the duct collar on the inlet end of the unit. (Optional)
2.
Remove the filter covering the face the coil.
3.
Wash it under warm water.
4.
Shake off excess water.
5.
Inspect and clean the face of the coil.
6.
Reinstall the filter.
7.
Replace the duct collar.

Cleaning the Condensate Drain System

The condensate drain system traps dust and dirt. Clean the drain system once a year.
1.
Shut off the rocker switch and unplug the unit.
2.
Remove the grille or duct on the evaporator inlet.
3.
Remove the filter and inspect the drain pan under the coil.
4.
If drain pan appears soiled, pour some hot water mixed with liquid bleach (diluted
solution) along the length of the pan to flush the dirt down the drain tube.
5.
Continue this treatment until the drain appears clean and free of dirt.
6.
Reinstall filter and grille or duct collar.
7.
Plug in the unit and restart.
Flushing a water regulating valve – water-cooled models only
To clear any sediment that may accumulate,
valves may be manually flushed by inserting
screwdrivers under both sides of the main
spring and lifting upwards to flush the valve.
Manual flushing does not affect valve
adjustments.
62
Sharp edges are present on the fins and
coils.