Wine Guardian Sentinel Series Installation, Operation And Maintenance Manual page 43

Wine cellar cooling systems
Table of Contents

Advertisement

Fan AUTO or
ON
Compressor
anti-short
cycling
Defrost sensor
enable/disable
Defrost cut-in
temperature
43
Setting 7
• Press "Settings" button to advance to
Setting 7.
• Press the "Up" or "Down" arrow buttons to
adjust number to the desired set point.
Factory default is zero (0).
Zero (0) = Auto–fan only turns on when
there is a call for cooling or heating
One (1) = Fan On–fan remains on
continuously
Setting 8
• Press "Settings" button to advance to
Setting 8.
• Press the "Up" or "Down" arrow buttons to
adjust to the desired time in one-minute
increments. Maximum is 10 minutes;
minimum is 3 minutes. Factory default is 5
minutes.
Compressor anti-short cycling time is the
amount of allowable time between
compressor stop and restart. Rapid
start/stop of compressors can cause
premature failure.
Setting 9
WINE GUARDIAN DOES NOT
• Press "Settings" button to advance to
RECOMMEND SETTINGS LOWER THAN
Setting 9.
FACTORY DEFAULT.
• Press the "Up" or "Down" arrow buttons to
adjust to the desired setpoint.
1 will equal enabled and a 0 (zero) will
equal disabled.
Setting 10
• Press "Settings" button to advance to
Setting 10.
• Press the "Up" or "Down" arrow buttons to
adjust to the desired setpoint. This setting is
adjustable from 25°F to 40°F. Factory
default is 39°F.
There must be at least a 1°F difference
between defrost cut-in and cut-out set
points.