Alarm Codes - Wine Guardian Sentinel Series Installation, Operation And Maintenance Manual

Wine cellar cooling systems
Table of Contents

Advertisement

Alarm Codes

High temperature
alarm
Flashing
temperature number
Low temperature
alarm
Flashing
temperature number
High humidity alarm
Flashing humidity
number
Low humidity alarm
Flashing humidity
number
!1 = High Pressure
Switch Fault
!2 = CS (Condensate
Switch Fault)
50
Flashing temperature number along
with (!) symbol will remain on screen
until temperature falls below the High
Temperature Alarm set point (Setting
3).
Flashing temperature number along
with (!) symbol will remain on screen
until temperature rises above the Low
Temperature Alarm set point (Setting
2).
Flashing humidity number along with (!)
symbol will remain on screen until
humidity falls below the High Humidity
Alarm setpoint (Setting 5).
Flashing humidity number along with (!)
symbol will remain on screen until
humidity rises above the Low Humidity
Alarm set point (Setting 4).
THIS ALARM FORCES THE SYSTEM
TO SHUT DOWN
(!1) will remain on screen until the High
Pressure reset switch has been reset.
See the trouble shooting guide page 57
for "Instructions to Reset High Pressure
Switch".
THIS ALARM FORCES THE SYSTEM
TO SHUT DOWN
(!2) will remain on screen until the CS
(condensate switch) fault is resolved
and reset.