Default mode
Fan AUTO or
ON
Compressor
anti-short
cycling
Defrost sensor
enable/disable
48
Setting 72
• Press "Settings" button to advance to
Setting 72.
• Press the "Up" or "Down" buttons to adjust
to the desired setpoint.
Initial mode set point. Will revert to this
setting upon loss of power.
1 = Auto
2 = Cool
3 = Heat
Setting 7
• Press "Settings" button to advance to
Setting 7.
• Press the "Up" or "Down" arrow buttons to
adjust number to the desired set point.
Factory default is zero (0).
Zero (0) = Auto–fan only turns on when
there is a call for cooling or heating
One (1) = Fan On–fan remains on
continuously
Setting 8
• Press "Settings" button to advance to
Setting 8.
• Press the "Up" or "Down" arrow buttons to
adjust to the desired time in one-minute
increments. Maximum is 10 minutes;
minimum is 3 minutes. Factory default is 5
minutes.
Compressor anti-short cycling time is the
amount of allowable time between
compressor stop and restart. Rapid
start/stop of compressors can cause
premature failure.
WINE GUARDIAN DOES NOT RECOMMEND
SETTINGS LOWER THAN FACTORY
DEFAULT.
Setting 9
• Press "Settings" button to advance to
Setting 9.
• Press the "Up" or "Down" arrow buttons to
adjust to the desired setpoint.
1 will equal enabled and a 0 (zero) will
equal disabled.