Alpha ESS Storion-SMILE-T10 Installation Manual page 31

Energy storage system
Hide thumbs Also See for Storion-SMILE-T10:
Table of Contents

Advertisement

Battery communication cable connection sequence: the RJ45 connector of the
communication cables shall go through the waterproof cap → through the sealing
ring→through the joint and inserted in to the COM port inside of the battery.
HV50056 & Battery communication cable connection sequence: the RJ45 connector
on one side shall go through the waterproof connector inserted into the COM port
inside the battery which is nearest to HV900112. The RJ45 connector on the other
side shall go through the waterproof cover inserted into the LMU port inside the
HV50056.
Note: The communication cable can go directly through waterproof seal-
ing ring, there is no need to make net cable on the spot.
Terminal Resistance: Insert the terminal resistance into the last COM port of the last
battery.
NOTES:
1. To remove the waterproof connector, it
shall be rotated counterclockwise according
to the installation procedure.
2. Use a screwdriver to remove the mainte-
nance baffle before wiring.
3. The battery has no circuit breaker for pro-
tection. Please be careful, do not short the
positive and negative terminals during in-
stallation.
4. The waterproof sealing ring needs to be
confirmed that it shall be inserted into the
plastic claw ring during installation.
30 / 55