Alpha ESS Storion-SMILE-T10 Installation Manual

Alpha ESS Storion-SMILE-T10 Installation Manual

Indoor energy storage system
Hide thumbs Also See for Storion-SMILE-T10:

Advertisement

Alpha ESS Co., Ltd.
+86 513 806 068 91
info@alpha-ess.com
www.alpha-ess.com
JiuHua Road 888, Nantong High-Tech Industrial
Development Zone, Nantong City, 226300
Alpha ESS Europe GmbH
+49 610 3459 1601
europe@alpha-ess.de
www.alpha-ess.de
Paul-Ehrlich-Straße 1a, 63225 Langen, Hessen
Alpha ESS Australia Pty. Ltd.
+61 402 500 520 (Sales)
+61 1300 968 933 (Technical Support)
australia@alpha-ess.com
www.alpha-ess.com.au
Suite 1, Level 1, 530 Botany Road, Alexandria,
NSW, 2015
Alpha ESS UK Co., Ltd
uk@alpha-ess.com
Drake House, Long Street, Dursley, gl11 4hh
Alpha ESS Suzhou Co., Ltd.
+86 512 6828 7609
info@alpha-ess.com
www.alpha-ess.com
Level 15,SIPC 158 Wangdun Road SIP Suzhou,
215028
Alpha ESS Italy S.r.l.
+39 599 239 50
info@alpha-ess.it
www.alpha-ess.it
Via Loda,17-41013 Castelfranco Emilia(MO)
Alpha ESS Korea Co., Ltd
+82 64 721 2004
korea@alpha-ess.com
2F, 19-4, Nohyeong 11-gil, Jeju-si, Jeju-do,
Republic of Korea
INSTALLATIONMANUAL
INSTALLATIONMANUAL
ENERGYSTORAGESYSTEM(ESS)
ENERGYSTORAGESYSTEM(ESS)
STORION-SMILE-T10 (INDOOR)
STORION-SMILE-T10(INDOOR)
V02.05292019

Advertisement

Table of Contents
loading

Summary of Contents for Alpha ESS Storion-SMILE-T10

  • Page 1 V02.05292019 INSTALLATIONMANUAL INSTALLATIONMANUAL ENERGYSTORAGESYSTEM(ESS) ENERGYSTORAGESYSTEM(ESS) STORION-SMILE-T10 (INDOOR) STORION-SMILE-T10(INDOOR) Alpha ESS Co., Ltd. Alpha ESS Suzhou Co., Ltd. +86 513 806 068 91 +86 512 6828 7609 info@alpha-ess.com info@alpha-ess.com www.alpha-ess.com www.alpha-ess.com JiuHua Road 888, Nantong High-Tech Industrial Level 15,SIPC 158 Wangdun Road SIP Suzhou,...
  • Page 2: Table Of Contents

    CONTENTS Copyright Statement This manual is under the copyright of Alpha ESS Co., Ltd, with all rights reserved. Please keep INTRODUCTION the manual properly and operate in strict accordance with all safety and operating instruc- tions in this manual. Please do not operate the system before reading through the manual.
  • Page 3: Introduction

    Grid Meter Grid Meter Grid 1.1 System Introduction AlphaESS Storion-SMILE-T10 (incl. M4856-S, HV50056 and SMILE-T10-INV) can be applied in DC-coupled systems (mostly new installation), AC-coupled systems (mostly retrofit) and Hybrid-coupled systems (mostly retrofit, and PV capacity-increase), as the Normal Loads...
  • Page 4: General Precautions

    Do not move the system when it is already connected with battery modules. Secure the system to prevent tipping with restraining straps in your vehicle. The transportation of AlphaESS Storion-SMILE-T10 must be made by the manufacturer or DC connectors: Installation...
  • Page 5: System Appearance

    Hexagon nuts Bracket (X2) communication Cable tie (X6) Black power line (X1) with flange (X4) line (X1) HV50056 Figure 5 Storion-SMILE-T10 Delivery Scope Object Description Hybrid Inverter with Cable Box HV50056 (High-voltage Control Box) M4856-S (BAT1) Screw package: Battery power cables:...
  • Page 6: Inverter Cable Box

    INTRODUCTION INTRODUCTION 1.4.1.2 LED Display Description Description BMS Com Port BAT in- In normal condition, LED display three status: LMU Com Port BAT in+ Earthing Point X 2 (Required To Connect Status Normal Protection Fault External LCD Wiring Port With Grounding Copper) Red and green Green light Red light...
  • Page 7: Installation

    (i) 1000 mm beyond the vertical sides of the SMILE-T10; (ii) 300 mm above the SMILE-T10; and (iii) To the extent of the bottom of the SMILE-T10. This Manual introduces the basic steps on how to install and set up Alpha ESS Storion-SMILE-T10 Please refer to Figure 10 M4856-S is a sealed component with no access to battery terminals or cell components within module.
  • Page 8 INSTALLATION INSTALLATION 2.2 Installation The top of the SMILE-T10 should be at least 300 mm from the ceiling or structure above the SMILE-T10, the ceiling or structure surface shall be suitably non-combustible for an area of 600 mm past the extremities of the SMILE-T10. Where more than 4 batteries are installed, some batteries shall be installed by the side, distance between two rows of batteries shall be not less than 100 mm SMILE-T10 shall be mounted with the highest point no greater than 2.2 m above the...
  • Page 9 INSTALLATION INSTRUCTIONS INSTALLATION Figure 15 Mounting Battery Figure 17 Placing the Rear Bracket of HV50056 Step 5 Insert the expansion tube into the drilled hole. Pass the expansion screw through the Step 8 Fix the HV50056 rear bracket with flange nuts on the two bracket of the top battery, as gasket and lock with a screwdriver, as Figure 15 shows.
  • Page 10: Wiring

    INSTALLATION INSTALLATION Hanging Position for the Inverter Hanging Position for the Inverter Figure 19 Installation of the Bracket A of the Inverter Figure 21 Installation of the HV50056 and the Inverter Step 10 Please remove the nuts from the rear bracket of HV50056 and fix the bracket A of the Step 12 Please hang the HV50056 on the rear bracket of HV50056 and hang the SMILE-T10-INV inverter on the rear bracket of HV50056 with the flange nuts, as shown in Figure 19.
  • Page 11 INSTALLATION INSTALLATION Step 5 Before wiring please remove the front maintenance baffle of the batteries with Step 7 Please connect the communication cables as referred in Figure 25 an across screwdriver. Figure 21 Installation of the HV50056 and the Inverter Figure 26 Communication Cables Battery power cable connection sequence: Battery communication cable connection sequence: the RJ45 connector of the...
  • Page 12 INSTALLATION INSTALLATION Step 8 Please connect one DC power cable from INV+ port on HV50056 to BAT+ port on SMILE-T10-INV, and another DC power cable from INV- port on HV50056 to BAT- port on SMILE-T10-INV. The AC auxiliary power cables which have been prewired onto the inverter, shall be connected to the AC auxiliary port on HV50056, as shown in Figure 27.
  • Page 13 INSTALLATION INSTALLATION Figure 28 Connection of the Communication Cables on the Inverter Side-Removing Waterproff Baffle FFigure 31 Connection of the Communication Cables on the Inverter Side Step 14 Please remove the cover of the cable box. Connect the AC cables to the corresponding ports.
  • Page 14: Power Meter

    INSTALLATION INSTALLATION 2.4 Power Meter 2.4.1.2 ADL-3000 (without CT, with meter plug), if applicable: The power meter should be installed and connected in the distribution box. There are two kinds of power meters, ADL-3000 and ACR10R, which users can choose from. ADL-3000: three-phase meter (with or without CT) ACR10R: three-phase meter with CT 2.4.1 Meter ADL-3000 (If Applicable)
  • Page 15 INSTALLATION INSTALLATION 2.4.1.3 ADL-3000 (with CT, without meter plug), if applicable: 2.4.1.4 ADL-3000 (with CT, with meter plug), if applicable: A PV meter will be ap-plied in an AC/hybrid system. A PV meter will be applied in an AC/hybrid system. Figure 40 ADL-3000 Connection (with CT, with Meter Plug) Note: When connecting CTs, pay attention to the current direction.
  • Page 16: Acr10R Meter (If Applicable)

    INSTALLATION INSTALLATION 2.4.2 ACR10R Meter (If Applicable) 2.4.3 Meter setting 2.4.3.1 ADL3000 Step 1 The initial interface of the meter Step 2 Click the “SET” button to enter the (normal working interface) is as shown password interface: below: Step 3 Click the "Enter" button to enter Step 4 Click the "Enter"...
  • Page 17: System Operation

    SYSTEM OPERATION INSTALLATION Step 9 Click the “SET” button again to Step 10 Click the “Enter” button to enter Step 10 Click the “Enter” button to enter the following interface, press the up and enter the save interface: the following interface, press the up and down arrow keys, and set “no”...
  • Page 18: Switch Off

    EMS INTRODUCTION AND SET UP EMS INTRODUCTION AND SET UP 3.2 Switch off Object Name Description System shall be turned off in the correct sequence to avoid any damage. Return Button: Escape from current interface or function Button Step 1 Remove the front panel of the inverter and HV50056 Up button: Move cursor to upside or increase value.
  • Page 19: Setting

    EMS INTRODUCTION AND SET UP EMS INTRODUCTION AND SET UP Figure 53 Work Mode Setting Figure 47 Battery Model Interface Figure 48 SOC Calibration Interface Figure 54 Force Charge Setting Interface Interface Step 5 Click the Battery Function and Step 6 Check SOC Calibration function set Step 11 If you want to use force charge, Step 11 Click the mode then set up work check battery type M4856-S.
  • Page 20: Ems Communication Checking

    EMS INTRODUCTION AND SET UP EMS INTRODUCTION AND SET UP AC\HYBRID system: Figure 60 Date&Time Setting Interface Figure 61 Ethernet interface Figure 65 Ethernet and Meter Figure 64 BMS Step 18 Click System in the setting Step 19 Click Ethernet to set the IP DC system: menu.
  • Page 21: System Registration

    5.1 System Setup in Monitoring system" to register new system at Alpha ESS. The system settings of the Storion-SMILE-T10 can be also carried in the installer monitoring. To do this, follow the steps below: Step 1 Please login in the installer account, click the list of storage systems and enter the SN.
  • Page 22: Other Information

    ON-LINE MONITORING ON-LINE MONITORING 5.1.2 Other Information Step 3 Finally, select the "Other Information" submenu and set the following parameter: - ACDC mode: it should be set - Time zone - maximum feed-in rate: In some countries you must set the maximum feed-in rate in % according complaint to the relevant regulation.
  • Page 23: Annex

    ANNEX ANNEX ANNEX 7.1 Datasheet – AlphaESS Storion-SMILE-T10 STORION SMILE-T10 Storion-SMILE-T10 Model YOUR System Specification SMART Nominal Output Power 10 000 VA ENERGY Max. DC Input Power 13 000 W* 12 000 W** Capacity Range 11.5 kWh ~ 23.0 kWh (90% DoD)