Rinnai Ember 600 Installation Manual page 15

Ember series gas fireplaces
Hide thumbs Also See for Ember 600:
Table of Contents

Advertisement

Check the size of the chimney before
doing anything. It needs to be at least
200 x 200 mm for the colinear flexi flue to
fit down.
When dropping the flexi flue down the
chimney make sure you have the intake
and exhaust flues in the correct position.
The intake is on the left.
Intake Ø 75 mm left hand side.
The Ember engine must be secured
to the enclosure via the top and side
flanges. This can be done directly into the
enclosure, into the infill panel or masonry
frame using the side brackets provided.
Make sure the chimney cap is
weathertight. Flexi flue also needs to be
secured to the flue cowl using the clamps
provided—these need to be riveted/
screwed in place to reduce the risk of
movement.
Exhaust Ø 100 mm right hand side.
Maximum flue length is 8 m.
Flexi flues clamped and riveted/screwed
in place to the engine spigot plate. Due
to the weight it's best to support the
underside of the plate to stop the flexi
flues from extending too much.
Base of masonry enclosure MUST BE
level and allow free movement of the
appliance for maintenance and servicing.
Ember Installation Guide: 12890-F 06-21 | 15