10.4
Status display in the display of the AMS
Display
PLB
(implausible measurement
values)
ATT
(insufficient received signal
level)
TMP
(operating temperature
outside of specification)
LSR
Laser diode warning
ERR
Hardware error
Notice!
Please use chapter 10 as a master copy should servicing be required.
Cross the items in the "Measures" column which you have already examined, fill out the
following address field and fax the pages together with your service contract to the fax
number listed below.
Customer data (please complete)
Device type:
Company:
Contact partner / department:
Phone (direct):
Fax:
Street / No:
ZIP code/City:
Country:
Leuze Service fax number:
+49 7021 573 - 199
Leuze electronic
Possible error cause
Laser beam interruption
Laser spot outside of reflector
Measurement range for maximum distance
exceeded
Velocity greater than 10 m/s
Ambient temperature far outside of the permissible
range (TMP display; PLB)
Reflector soiled
Glass lens of the AMS soiled
Performance reduction due to snow, rain, fog, con-
densing vapor, or heavily polluted air (oil mist, dust)
Laser spot only partially on the reflector
Protective foil on the reflector
Ambient temperatures outside of the specified
range
Laser diode prefailure message
Indicates an uncorrectable error in the hardware
AMS 301
Diagnostics and troubleshooting
301i
Laser spot must always be incident on the reflector.
Traverse rate < 10 m/s?
Restrict traversing path or select AMS with larger
measurement range.
Reduce velocity.
Select AMS with heating or ensure cooling.
Clean reflector or glass lens.
Optimize usage conditions.
Check alignment.
Remove protective foil from reflector.
In case of low temperatures, remedy may be an
AMS with heating.
If temperatures are too high, provide cooling or
change mounting location.
Send in device at next possible opportunity to have
laser diode replaced. Have replacement device
ready.
Send in device for repair.