10.1.2 Diagnostics; 10.1.3 Expanded Diagnostics; General Causes Of Errors; 10.2.1 Power Led - Leuze electronic AMS 301i Manual

Optical laser measurement system
Table of Contents

Advertisement

Diagnostics and troubleshooting

10.1.2 Diagnostics

The diagnostics function is activated by selecting the Diagnostics menu item. The ESC
button
deactivates the diagnostics function and clears the contents of the recordings.
ESC
The recorded diagnostic data are displayed in 2 fields. In the upper half of the display, status
messages of the AMS and the bar graph are displayed. The lower half contains information
that assists in a Leuze-internal evaluation.
IO1
LSR
IO2 TMP
ERR
Pos. current: --------
Pos. min.:
Pos. max.:
Use the up/down buttons
contents of the scrollable pages are intended solely for Leuze for internal evaluation.
The diagnostics have no influence on the communication to the host interface and can be
activated during operation of the AMS 301i.

10.1.3 Expanded diagnostics

The Expanded diagnostics menu item is used for Leuze-internal evaluation.
10.2

General causes of errors

10.2.1 Power LED

See also chapter 8.2.2.
Error
PWR LED "OFF"
PWR-LED "flashes red"
PWR-LED "static red"
Table 10.1:
10.3

Interface errors

10.3.1 BUS LED

The LED does not show a bus failure with the AMS 301i.
53
PLB
ATT
--------
--------
Possible error cause
No supply voltage connected
Hardware error
Light beam interruption
Plausibility error
Hardware error
General causes of errors
to scroll in the bottom half between various displays. The
i
AMS 301
Measure
Check supply voltage.
Send in device.
Check alignment.
Traverse rate >10m/s.
For error description, see display,
It may be necessary to send in the device.
Leuze electronic