AMS 304 Optical Laser Measurement System PROFIBUS / SSI T E C H N I C A L D E S C R I P T I O N...
Page 2
Leuze electronic GmbH + Co. KG P.O. Box 1111, D- 73277 Owen / Teck Tel. +49(0) 7021/ 573-0, Fax +49(0)7021/ 573-199 Sales and Service Germany Sales Region North Sales Region South Sales Region East Phone 035027/629-106 Phone 07021/573-306 Phone 07021/573-307...
Page 3
304i The main menus Device information - main menu AMS 304i 120 Leuze electronic This menu item contains detailed information on • Device model, GmbH & Co. KG • Manufacturer, SW: V 1.3.0 HW:1 • Software and hardware version, SN: ----------------------- •...
Notice! The Declaration of Conformity for these devices can be requested from the manufacturer. The manufacturer of the product, Leuze electronic GmbH + Co. KG in D-73277 Owen/Teck, possesses a certified quality assurance system in accordance with ISO 9001. LISTED...
With the AMS 3xxi product series, Leuze electronic makes available a range of internationally relevant interfaces. Note that each interface version listed below corresponds to a different 3xxi model.
They correspond to the state of the art. Intended use The AMS 304i… device series is an absolute measuring system based on laser technology. The devices use a visible optical laser to measure distances of up to 300 m contactlessly.
Electrical work must be carried out by a certified electrician. Attention, laser radiation! The AMS 304i operates with a red light laser of class 2 acc. to EN 60825-1. If you look into the beam path over a longer time period, the retina of your eye may be damaged!
Page 12
For EtherNet-based devices, the MAC ID is specified on the name plate. Please note that the shown name plate is for illustration purposes only; the contents do not correspond to the original. Figure 2.1: Location of the name plate on the AMS 304 AMS 304 Leuze electronic...
Fast commissioning / operating principle Fast commissioning / operating principle Notice! Below, you will find a short description for the initial commissioning of the AMS 304i. Detailed explanations for the listed points can be found throughout the handbook. Mounting the AMS...
Activate the desired modules (at least one module). Store the slave address for the AMS 304i in the PROFIBUS manager. Ensure that the address is the same as the address configured in the device. Detailed information can be found in chapter 9. AMS 304 Leuze electronic...
10 °C: 120.000 h Interfaces ≤ 12 Mbit/s PROFIBUS DP to V, V1 SSI clock rate 50 kHz … 800 kHz Operating and display elements Keyboard 4 buttons Display monochromatic graphical display, 128 x 64 pixels 2 LEDs, two-colored Leuze electronic 304i...
Page 16
A 100% prevention of the formation of condensation cannot be guaranteed due to the limited heating capacity of the AMS 304i. This is a Class A product. In a domestic environment this product may cause radio interference, in which case the operator may be required to take adequate measures.
Dimensioned drawing AMS 304i M 5 screw for alignment Knurled nut with WAF 4 hexagon socket and M 5 nut for securing Optical axis Zero point of the distance to be measured Figure 4.1: Dimensioned drawing AMS 304 Leuze electronic 304i...
Device name plate using the AMS 300 as an example Notice! Please note that the shown name plate is for illustration purposes only; the contents do not correspond to the original. Save the original packaging for later storage or shipping. Leuze electronic AMS 304...
Installation and mounting If you have any questions concerning your shipment, please contact your supplier or your local Leuze electronic sales office. Observe the applicable local regulations when disposing of the packaging materials. Mounting the AMS 304i M 5 screw for...
Page 21
("B" in figure 5.2). Knurled nut and nut must not be tightened until alignment has been completed. Attention! The device must not be opened. Failure to comply will render the guarantee void. Warranted features cannot be guaranteed after the device has been opened. Leuze electronic AMS 304...
Optional mounting bracket A mounting bracket for mounting the AMS 304i on a flat, horizontal surface is available as an optional accessory. Type designation: MW OMS/AMS 01 Part no.: 50107255 Laser beam Figure 5.3: Optional mounting bracket AMS 304 Leuze electronic...
Depending on the size of the used reflector, the optical data transceiver can be mounted with a minimum mounting spacing of 100 mm to the AMS 304i. The mounting spacing is independent of the distance.
AMS 304i… and the deflection mirror as well as between the mirror and the reflector. Use the M5 screws to mount the deflector unit. Secure the screws with a toothed lock washer to protect against loosening caused by vibrations.
Installation and mounting 5.3.2 Dimensioned drawing of US AMS 01 deflector unit Laser beam Figure 5.6: Dimensioned drawing of US AMS 01 deflector unit Leuze electronic AMS 304...
A Mirror Figure 5.7: Photo and dimensioned drawing of the US 1 OMS deflector unit Alignment of the laser light spot on the reflector is performed as described in chapter 5.2. AMS 304 Leuze electronic...
304i measures distances against a reflective tape specified by Leuze electronic. All provided specifications for the AMS 304i, such as the operating range or accuracy, can only be achieved with the reflective tape specified by Leuze electronic. The reflective tapes are available as adhesive tapes, affixed to a metal plate and with an integrated heater especially for use at low temperatures.
Do not use any agents that act with a grinding effect. A conventional household Cleaning detergent can be used as a cleaning agent. Rinse with clear water and dry the surface. Storing the reflector Store in a cool and dry place. AMS 304 Leuze electronic...
Dimensioned drawing of reflective tape on a metal plate Always align the TOP marking with the AMS connections! (chapter 6.4.2) Figure 6.1: Dimensioned drawing of reflectors Part Reflective tape (mm) Reflector plate (mm) Reflective tape 200x200-M Reflective tape 500x500-M Reflective tape 914x914-M Leuze electronic AMS 304...
Do not use any agents that act with a grinding effect. A conventional Cleaning household detergent can be used as a cleaning agent. Rinse with clear water and dry the surface. Storing the reflector Store in a cool and dry place. AMS 304 Leuze electronic...
Attention! The reflector sizes shown below are a recommendation from Leuze electronic for on-vehicle mounting of the AMS 304i. For stationary mounting of the AMS 304i, a smaller reflector is generally sufficient for all measurement distances. On the basis of the system planning and design, always check whether mechanical travel tolerances may require the use of a reflector larger than that which is recommended.
For this purpose, use the alignment elements provided on the AMS 304i… (see chapter 5.2 "Mounting the AMS 304i"). If necessary, remove the protective foil from the reflector.
Page 34
Reflective tapes …-S and …-M Pitch 1 ° Direct reflection from the triad structure Deflected surface reflection due to the pitch of the reflective tape Figure 6.3: Reflector mounting Pitch 1 ° Spacer sleeves Figure 6.4: Pitch of the reflector AMS 304 Leuze electronic...
Page 35
Direct reflection from the triad structure Deflected surface reflection due to the pitch of the reflective tape Figure 6.5: Mounting of heated reflectors Pitch approx. 1 ° Spacer sleeves Figure 6.6: Pitch of the heated reflector Leuze electronic AMS 304...
Notice! Reliable function of the AMS 304i and, thus, max. operating range and accuracy can only be achieved with the reflective tape specified by Leuze electronic. No function can be guaranteed if other reflectors are used! AMS 304 Leuze electronic...
For UL applications, use is permitted exclusively in Class 2 circuits according to NEC (National Electric Code). The laser measurement systems are designed in accordance with safety class III for supply by PELV (protective extra-low voltage with reliable disconnection). Leuze electronic AMS 304...
Receive/transmit data A-line (N) N.C. GNDP Data reference potential GNDP 3 B (P) Receive/transmit data B-line (P) SHIELD Shield or functional earth B (P) M 12 connector Thread Functional earth (housing) (B-coded) Table 7.2: Pin assignments for BUS IN AMS 304 Leuze electronic...
Voltage supply 0 V DC RS232-RX Receiving line RS 232/service data Not used RS232-RX M 12 socket Thread Functional earth (housing) (A-coded) Table 7.5: Service pin assignments Notice! The service interface is designed only for use by Leuze electronic! AMS 304 Leuze electronic...
Display and control panel AMS 304i Display and control panel AMS 304i Structure of the control panel Status display Bus/interface info Bar graph Distance measurement value Control buttons Figure 8.1: Structure of the control panel using the AMS 304 PROFIBUS device variant as an example...
Page 42
Display and control panel AMS 304i Warning - laser prefailure message: Laser diode old, device still functional, exchange or have repaired. Warning - temperature monitoring: Permissible internal device temperature exceeded / not met. Plausibility error: Implausible measurement value. Possible causes: light beam interruption, outside of measurement range, permissible internal device temperature considerably exceeded or traverse rate >10m/s.
Display and control panel AMS 304i 8.2.2 LED status displays PWR LED Device OFF - No supply voltage Flashing green Power LED flashes green - No measurement value output - Voltage connected - Self test running - Initialization running - Parameter download running...
Display and control panel AMS 304i Green continuous light BUS LED green - AMS 304i PROFIBUS communication active, bus ok Flashing green BUS LED flashes green - AMS 304i not on the bus Red flashing BUS LED flashes red - Configuration failed ("parameter failure")
Display and control panel AMS 304i Setting values If input of a value is possible, the display looks like this: Delete character Enter digit <-|0123456789 save Default ----------------- unit Save Use the buttons to set the desired value. An accidental, incorrect entry can be corrected by selecting <-| and then pressing...
Display and control panel AMS 304i Status and measurement data - main menu IO2 TMP • Display of status-, warning-, and error messages. • Status overview of the switching inputs/outputs • Bar graph for the reception level • Link + 87.000 m •...
Page 47
Display and control panel AMS 304i Table 8.1: Parameter handling submenu Level 3 Level 4 Level 5 Selection/configuration option Standard Description Parameter ON / OFF enabling The standard setting (OFF) prevents unintended parameter changes. With parameter enabling activated (ON), the display is inverted. In this state, it is possible to change parameters manually.
Page 48
Display and control panel AMS 304i Table 8.3: SSI submenu Level 3 Level 4 Level 5 Selection/configuration option Standard Description SSI resolution 0.001 mm / 0.01 mm / 0.1 mm / 1 mm / 10 mm / free resolution 0.1 mm The measurement value can be displayed in these resolutions.
Page 49
Display and control panel AMS 304i Table 8.4: Position value submenu Level 3 Level 4 Level 5 Selection/configuration option Standard Description Position value in Last valid value / zero Null the case of error Specifies which position value is output after the error delay time elapses.
Display and control panel AMS 304i Other submenu Table 8.6: Other submenu Level 3 Level 4 Level 5 Selection/configuration option Standard Description Heating control Standard (10° C … 15° C)/Extended (30° C … 35° ) Standard Defines a switch-on/switch-off range for the heating control.
Display and control panel AMS 304i 8.3.4 Service menu Service Status messages Diagnostics Expanded diagnostics A more detailed description of the individual functions can be found in chapter 11. Operation Described here is an operating process using parameter enabling as an example.
Page 52
Notice! Parameters which are defined in a GSD file have priority. After deactivation of parameter enabling on the AMS 304i, the parameter defined in the control are reactivated. The address setting is not overwritten. For the SSI interface, the communication between the control and the AMS...
The PROFIBUS interface can be activated/deactivated via the display. To activate / deactivate the interface, parameter enabling must be activated (see chapter 8.3.2). The respectively active interface is shown in the display; when PROFIBUS is activated, the address set is visible in the display. Leuze electronic AMS 304...
BUS OUT. If the laser measurement system is the last subscriber in the network, the BUS OUT connection must be connected to a terminator plug, see "Accessory terminating resistor" on page 102.. AMS 304 Leuze electronic...
During operation of the laser measurement system on the PROFIBUS all parameters are set to default values. If these parameters are not changed by the user, the device functions using the default settings supplied by Leuze electronic. For the default settings of the device please refer to the following module descriptions.
Page 56
PROFIBUS interface Notice! Some controls make available a so-called "universal module". This module must not be activated for the AMS 304i. Attention! The AMS 304i makes available a PROFIBUS and an SSI interface. Both interfaces can be operated in parallel. If the AMS...
The individual modules are numbered from 1 … 19. The parameters and input/output data within a module are from … Example: preset parameter in module 2 becomes active only when the preset teach occurs via module 2 , 4 or 5 . Leuze electronic AMS 304...
Page 60
32 bit The resolution of the offset value is inde- pendent of the resolution selected in module 1. The entered offset applies immediately without any further release. Parameter length: 6 bytes see following notice! AMS 304 Leuze electronic...
Page 61
Description Rel. Data Value Default Unit CR to addr. type module metr. Inch sign Output of the current position. -999999 … +999999 – scaled 32 bit Position value Input data length: 4 bytes consistently Output data Leuze electronic AMS 304...
Page 62
CR to addr. type module metr. Inch Read in the preset value. 0 1 Preset teach – – Preset teach Preset value is deactivated. 0 1 Preset teach – – Preset reset Output data length: 1 byte AMS 304 Leuze electronic...
Page 63
The output data apply to all interfaces. sign -999999 … +999999 – in/100 The resolution of the preset value is 32 bit Preset independent of the resolution selected in module 1. Output data length: 5 bytes Leuze electronic AMS 304...
Page 64
(valid for static or dynamic preset). … teach function – Input 8 bit Laser 010 = HW input as laser OFF The HW input is used as laser OFF. function Parameter length: 4 bytes AMS 304 Leuze electronic...
Page 65
Corridor change of a high-bay storage device during which the laser diode is not switched off while travelling around curves. Measurement distance 100 m –> t = 5 sec., measurement distance 200 m –> t = 10 sec. Leuze electronic AMS 304...
Page 66
The output can be activated/deactivated active with this bit. The corresponding release – – is performed in module 4, output param- State 1: Output at signal level eter bit 2.0. active Output data length: 1 byte AMS 304 Leuze electronic...
Page 67
001 = HW input as preset Input input (valid for static or dynamic preset). teach function Laser 010 = HW input as laser OFF The HW input is used as laser OFF. function Parameter length: 4 bytes Leuze electronic AMS 304...
Page 68
Corridor change of a high-bay storage device during which the laser diode is not switched off while travelling around curves. Measurement distance 100 m –> t = 5 sec., measurement distance 200 m –> t = 10 sec. AMS 304 Leuze electronic...
Page 69
The output can be activated/deactivated active with this bit. The corresponding release – – State is performed in module 5, output param- 1: Output at signal level eter bit 2.0. active Output data length: 1 byte Leuze electronic AMS 304...
Page 70
1. position limit 1: Value less than limit value 1 0: OK Signals that the value is greater than Upper – – – upper limit value 1. position limit 1: Value greater than limit value 1 AMS 304 Leuze electronic...
Page 71
Input data length: 2 bytes Output data Output data Description Rel. Data Value Default Unit CR to addr. type module metr. Inch 0: Laser ON Controls the laser. – – – Laser 1: Laser OFF Output data length: 2 bytes Leuze electronic AMS 304...
Page 72
Hex code of the "position limit value range 1" parameter The value listed in this table shows the hex coding of the default settings: 00 00 00 00 00 00 00 00 Input data Output data AMS 304 Leuze electronic...
Page 73
Hex code of the "position limit value range 2" parameter The value listed in this table shows the hex coding of the default settings: 00 00 00 00 00 00 00 00 Input data Output data Leuze electronic AMS 304...
Page 74
– Specifies whether the PLB status bit is 0: OFF set immediately in the event of an error Suppress – – or if it is suppressed for the configured velocity 1: ON velocity suppression time. status AMS 304 Leuze electronic...
Page 75
Parameter length: 6 bytes Hex code of the "Error handling procedures" parameter (position and velocity) The value listed in this table shows the hex coding of the default settings: 00 64 00 C8 Input data Output data Leuze electronic AMS 304...
Page 76
In the default setting a positive velocity is output when the reflector moves away from the AMS 304i. When the reflector moves towards the AMS 304i, negative velocities are output. If the "negative" count direction is configured in module 1, the velocity signs are reversed.
Page 77
Input data Input data Description Rel. Data Value Default Unit CR to addr. type module metr. Inch sign Current velocity. -999999 … +999999 scaled – 32 bit Velocity Input data length: 4 bytes consistently Output data Leuze electronic AMS 304...
Page 78
– beginning at this position. 32 bit range start The velocity limit value is monitored up sign … -999999 … +999999 – Limit value 1 to this position. 32 bit range end Parameter length: 13 bytes AMS 304 Leuze electronic...
Page 79
Hex code of the "static velocity limit value 1" parameter The value listed in this table shows the hex coding of the default settings: 00 00 00 64 00 00 00 00 00 00 00 00 Input data Output data Leuze electronic AMS 304...
Page 80
32 bit range start The velocity limit value is monitored up sign … -999999 … +999999 in/100 – Limit value 2 to this position. 32 bit range end Parameter length: 13 bytes AMS 304 Leuze electronic...
Page 81
Hex code of the "static velocity limit value 2" parameter The value listed in this table shows the hex coding of the default settings: 00 00 00 64 00 00 00 00 00 00 00 00 Input data Output data Leuze electronic AMS 304...
Page 82
– beginning at this position. 32 bit range start The velocity limit value is monitored up sign … -999999 … +999999 – Limit value 3 to this position. 32 bit range end Parameter length: 13 bytes AMS 304 Leuze electronic...
Page 83
Hex code of the "static velocity limit value 3" parameter The value listed in this table shows the hex coding of the default settings: 00 00 00 64 00 00 00 00 00 00 00 00 Input data Output data Leuze electronic AMS 304...
Page 84
32 bit range start The velocity limit value is monitored up sign … -999999 … +999999 in/100 – Limit value 4 to this position. 32 bit range end Parameter length: 13 bytes AMS 304 Leuze electronic...
Page 85
Hex code of the "static velocity limit value 4" parameter The value listed in this table shows the hex coding of the default settings: 00 00 00 64 00 00 00 00 00 00 00 00 Input data Output data Leuze electronic AMS 304...
Page 86
32 bit range start The velocity limit value is monitored up sign … -999999 … +999999 in/100 – Limit value to this position. 32 bit range end Output data length: 13 bytes consistently AMS 304 Leuze electronic...
Page 87
1: Comparison active limit value 2 0: Comparison not active Signals whether the current velocity is Velocity – – – compared with this limit value. comparison 1: Comparison active limit value 3 Leuze electronic AMS 304...
Page 88
1: Comparison active limit value 4 0: Comparison not active Signals whether the current velocity is Dynamic – – – compared with this limit value. velocity com- 1: Comparison active parison Input data length: 2 bytes Output data AMS 304 Leuze electronic...
Page 89
If the SSI interface is not configured via module 17 (SSI interface) in PROFIBUS operation, the SSI interface is deactivated. If the SSI interface is operated without PROFIBUS (PROFIBUS OFF/SSI ON), configuration is performed via the display. Leuze electronic AMS 304...
Page 90
0: OFF Laser (LSR) 1: Error – – Laser prefailure message. 1: ON 0: OFF Plausibility (PLB) – – Plausibility error. 1: ON 0: OFF Hardware (ERR) – – Hardware error. 1: ON Parameter length: 2 bytes AMS 304 Leuze electronic...
Page 91
1.704 m ≈ 26-bit; resolution 0.01 671 m 6,710 in 170 m ≈ 26-bit; resolution 0.001 67 m 671 in 17 m Figure 9.19: SSI interface - resolution and maximum position value which can be represented Leuze electronic AMS 304...
Page 92
(30 °C … 35 °C) heating capacity. This parameter is available as stan- dard, but functions only for devices with integrated heating (AMS 304 … H). Parameter length: 4 bytes AMS 304 Leuze electronic...
Page 93
PROFIBUS interface Hex coding of the "other" parameter The value listed in this table shows the hex coding of the default settings: Input data Output data Leuze electronic AMS 304...
Page 94
Due to the free resolution in the exam- ple, an internal measurement value of 3333 mm gives an output value of “1111”. The resolution of the “Offset", "Preset" and "Limit values" parameters is not affected by free resolution. Parameter length: 4 bytes AMS 304 Leuze electronic...
The SSI interface can only represent positive distance values. If negative output values are ascertained due to the offset or count direction, a zero value is output at the SSI interface! In the event of a number overflow, all data bits are set to "1". Leuze electronic AMS 304...
The data can be read out with a clock rate between 80 kHz and 800 kHz. Attention! Updating the measurement values on the SSI interface of the AMS 304i: The measurement value on the SSI interface of the AMS 304i is updated every 1.7 ms...
Position output: 0 Suppress position status: active Position suppression time: 100 ms Display language English Display illumination OFF after 10 min. Display contrast Medium Password protection Password 0000 Table 10.2: Default settings of the SSI interface AMS 304 Leuze electronic...
For basic operation of the display please refer to chapter 8.2.3. In order to change the parameters please activate parameter enabling. The SSI interface remains active even during parameter enabling. Changes to parameters have an immediate effect. Leuze electronic AMS 304...
Diagnostics and troubleshooting Diagnostics and troubleshooting 11.1 Service and diagnostics in the display of the AMS 304i In the main menu of the AMS 304i, expanded "Diagnostics" can be called up under the Service heading. Service Status messages Diagnostics Expanded diagnostics...
Leuze for internal evaluation. The diagnostics have no influence on the communication to the host interface and can be activated during operation of the AMS 304i. 11.1.3 Expanded diagnostics The Expanded diagnostics menu item is used for Leuze-internal evaluation.
(sporadic error at the • Avoid EMC coupling caused by power cables laid PROFIBUS) parallel to device lines. Overall network expansion exceeded Check max. network expansion as a function of the baud rate set. Table 11.2: Bus error AMS 304 Leuze electronic...
N.C. B (P) B (P) M 12 socket Thread functional earth (housing) (B-coded) A (N) N.C. N.C. N.C. B (P) M 12 connector (B-coded) Conductor with insulation red Conductor with insulation green Drain wire Fibrous fleece Leuze electronic AMS 304...
Page 108
KB PB-10000-BA M 12 socket for BUS IN, axial connector, open cable end, 50104179 cable length 10 m KB PB-15000-BA M 12 socket for BUS IN, axial connector, open cable end, 50104178 cable length 15 m AMS 304 Leuze electronic...
Page 109
KB SSI/IBS-25000-BA M 12 socket, B-coded, for SSI/Interbus, axial connector, 50108447 open cable end, cable length 25 m KB SSI/IBS-30000-BA M 12 socket, B-coded, for SSI/Interbus, axial connector, 50108446 open cable end, cable length 30 m Leuze electronic AMS 304...
Contact your Leuze distributor or service organization should repairs be required. The addresses can be found on the inside of the cover and on the back. Notice! When sending the laser measurement systems to Leuze electronic for repair, please provide an accurate description of the error. 13.3...
Page 111
Contrast ......89 Illumination ....89 Distance to an adjacent DDLS 200 ..20 Leuze electronic 304i...
Page 113
Limit value 4 ....55 Status ..... . . 55 Leuze electronic 304i...
Page 114
Menu structure AMS 304i Level 1 Level 2 Level 3 Level 4 Level 5 Selection/configuration option Detailed information on : selection : selection : selection : selection : selection : selection : back : back : back : back : activate : back Device information page 42...
Page 115
57.6 kbit/s / 115.2 kbit/s Format 8,e,1 / 8,n,1 Language selection Deutsch / English / Español / Français / Italiano page 47 Service Status messages page 48 Diagnostics Exclusively for service purposes by Leuze electronic Expanded diagnostics Exclusively for service purposes by Leuze electronic...