Leuze electronic AMS 301i Manual page 45

Optical laser measurement system
Table of Contents

Advertisement

Table 8.2:
Level 3
Position
resolution
Velocity
resolution
Position value submenu
Table 8.3:
Level 3
Measurement
unit
Count direction
Offset
Preset
Free resolution
value
Error delay
Position value in
the case of error
Leuze electronic
RS 485 submenu
Level 4
Level 5
Selection/configuration option
Description
0.01 mm / 0,1 mm / 1 mm / 10 mm / free mm
The measurement value can be displayed in these resolutions.
The value of the free resolution is determined in the "Position value"
submenu in the "Value of free resolution" parameter.
1 / 10 / 100
Position value submenu
Level 4
Level 5
Selection/configuration option
Description
Metric/Inch
Specifies the units of the measured distances.
Positive/Negative
Positive: The measurement value begins at 0 and increases with increas-
ing distance.
Negative: The measurement value begins at 0 and decreases with
increasing distance. Negative distance values may need to be compen-
sated with an offset or preset.
Output value=measurement value+offset.
The resolution of the offset value is independent of the selected "Reso-
lution position" and is entered in mm or inch/100. The offset value is
effective immediately following entry. If the preset value is activated, this
has priority over the offset. Preset and offset are not offset against each
other.
The preset value is accepted by means of teach pulse. The teach pulse
can be applied to a hardware input of the M 12 PWR connector. The hard-
ware input must be appropriately configured. See also configuration of
the I/Os.
The measurement value can be resolved in increments of 1/1000 within
the 5 ... 50000 value range. If, e.g., a resolution of 0.875 mm per digit
is required, the parameter is set to 875.
In the activated interface, the measurement value display must also be
set to "free resolution" ("Resolution position" parameter).
ON / OFF
Specifies whether, in the event of an error, the position value immediately
outputs the value of the "Position value in the case of error" parameter
or the last valid position value for the configured error delay time.
Last valid value / zero
Specifies which position value is output after the error delay time elapses.
Display and control panel AMS 301i
i
AMS 301
Standard
0.1 mm
1
Standard
Metric
Positive
0 mm
0 mm
1000
ON/100 ms
Zero
42